beautypg.com

Device description – KROHNE H250 M40 ATEX II3G Ex nA EN User Manual

Page 13

background image

DEVICE DESCRIPTION

2

13

H250 M40

www.krohne.com

01/2012 - 4001485201- MA H250/M40-Ex-II3G-AD R01 en

Reference point consideration

Reference point consideration

Reference point consideration

Reference point consideration

The permissible product and ambient temperatures may be exceeded or undershot as long as
the permissible temperature range of the reference point of the display is not exceeded. The
following table contains the permissible maximum values at the reference point. Note:

• Reference point is the connection of the equipotential bonding conductor of the M40 indicator.
• The temperatures at the reference point are to be determined in the most unfavourable

operating situation.

• The required measuring uncertainty is max. 2K.
• Measuring conditions and results are to be permanently recorded in a suitable format.
• The measuring unit should be insulated properly.

Maximum permitted temperatures at reference point of indicator in °C

Design of
indicator

Component

Permitted temperature range at reference point T [°C] according to
temperature class

TK T6

T5

T4 ... T1

M40./../K.

SC3,5-NO-Y

-20 ... +65

-20 ... +80

-20 ... +90

SJ3,5-SN

-20 ... +66

-20 ... +81

-20 ... +90

SJ3,5-S1N

-20 ... +66

-20 ... +81

-20 ... +90

I7S23,5-N

-40 ... +70

-40 ... +85

-40 ... +90

M40./../ESK4/K.

SC3,5-NO-Y

-20 ... +55

-20 ... +70

-20 ... +80

SJ3,5-SN

-20 ... +55

-20 ... +70

-20 ... +80

SJ3,5-S1N

-20 ... +55

-20 ... +70

-20 ... +80

I7S23,5-N

-40 ... +55

-40 ... +70

-40 ... +80

M40./../ESK4

ESK4

-40 ... +55

-40 ... +70

-40 ... +80

M40./../ESK4-T

ESK4 and I/O modul

-40 ... +52

-40 ... +67

-40 ... +77

M40./../ESK4-FF

ESK4 and ESK4-FF

-40 ... +36

-40 ... +51

-40 ... +76

M40./../ESK4-PA

ESK4 and ESK4-PA

AD_H250_M40_II3G_R01_en_4001485201_PRT.book Page 13 Tuesday, January 24, 2012 8:46 AM