Maximum permitted product temperature in °F
Maximum permitted product temperature T
m
[°F]
Heating
jacket
TK
T6
T5
T4
T3
T2, T1
None
with
HT
version
T
amb
[°F]
≤ 104 ≤ 140 ≤ 149
≤ 140 ≤ 149 ≤ 104 ≤ 140 ≤ 149 ≤ 104 ≤ 140 ≤ 149
ESK4
DN15
DN25
DN50
DN15
DN25
185
212
194
275
275
392
320
284
455
320
284
x
185
212
212
275
275
392
392
392
572
572
518
DN80
DN100
DN50
DN80
185
212
185
275
266
392
302
266
428
302
266
x
185
212
212
275
275
392
392
392
572
572
491
ESK4-T
DN15
DN25
DN50
DN15
DN25
185
194
158
275
248
392
284
248
428
284
248
x
185
212
185
275
275
392
392
392
572
554
437
DN80
DN100
DN50
DN80
185
185
158
266
239
392
266
239
392
266
239
x
185
212
176
275
275
392
392
392
572
518
419
ESK4-FF / ESK4-PA
DN15
DN25
DN50
DN15
DN25
158
140
not
admissi
ble
275
257
392
302
257
455
302
257
x
185
140
275
275
392
392
392
572
572
464
DN80
DN100
DN50
DN80
149
140
275
248
392
284
248
428
284
248
x
185
140
275
275
392
392
392
572
572
437
K1/K2
DN15
DN25
DN50
DN15
DN25
185
212
212
275
275
392
392
356
554
401
356
x
185
212
212
275
275
392
392
392
572
572
572
DN80
DN100
DN50
DN80
185
212
212
275
275
392
365
338
500
365
338
x
185
212
212
275
275
392
392
392
572
572
572
AD_H250_M40_II3G_R01_en_4001485201_PRT.book Page 11 Tuesday, January 24, 2012 8:46 AM