Jenway 7305 User Manual
Page 27
7.1.2
PRintinG ReSULtS
Results displayed in the expanded operating menu can
be printed by pressing the key adjacent to the
printer
icon. Depending on the printout destination previously
selected the result will be sent to the internal printer
or the external printer. If the printer icon is pressed
when there is not a result on the screen the
no result
to printer or no result to RS232 icon (depending on
results destination) will flash up on the screen.
7.2
AUtoLoGGinG
The
autolog function enables repeat measurements of
the same sample to be performed with a set time period
between each measurement. This produces a batch
of results for the same sample. The autolog function
also enables the results to be autologged to different
destinations. The autolog menu is accessed from the
utility toolbar in the expanded operating menu by
pressing the key adjacent to the
autolog icon.
7.2.1
Setting the number of Sample Repetitions
To set the number of repeat measurements of the same
sample press the key below the
sample icon and use the
keys adjacent to the
arrow icons to increase or decrease
the number of repetitions required. To reset the number
to zero press and hold the key below the
sample icon
for 2 seconds.
To set the time period between each measurement press
the key below the
timer icon and use the keys adjacent
to the
arrow icons to increase or decrease the time in 1
second intervals. To reset the time to one second press
and hold the key below the
timer icon for 2 seconds.
Once the required number of repetitions and time
interval have been selected press the key adjacent to the
tick icon to save the changes and return to the expanded
operating menu.
The number of repetitions and time period will be
displayed below the autolog icon. To commence
autologging press the key below the measure
sample
icon. Once the first measurement has been performed
the time period starts counting down until it reaches zero
and then the next measurement will be taken.
This will reduce the repetition number by one. When the number of repetitions reaches zero, autologging
is complete. Autologging can be stopped before all the measurements have been completed by pressing
the key adjacent to the
autolog icon. Confirmation will be needed to stop autologging. Press the key
adjacent to the
tick icon to confirm stopping autologging or press the key adjacent to the cross icon to
continue autologging.
0.132
73.8
400
09:02
ABS
%T
nm
0.000
0.000
600
09:02
ppm
ABS
nm
0002x
003s
0005
010s
X
0.000
0.000
600
09:02
ppm
ABS
nm
0002x
003s
27
0005
010s
X