HT instruments HT210 User Manual
Page 17

HT210
EN - 16
Range Resolution
Accuracy
Sensibilità Overload
protection
0.5 - 99%
0.1%
±(1.2%rdg + 2dgt)
>8Vrms 250VDC/ACrms
100
µs< durata impulso <100ms
Range frequenza: 5Hz
÷ 150Hz
Capacitance (Autorange)
Range Resolution
Accuracy
Overload
protection
40.00nF 0.01nF
±(5.0%rdg + 7dgt)
250VDC/ACrms
400.0nF 0.1nF
±(3.0%rdg + 5dgt)
4.000
µF 0.001µF
40.00
µF 0.01µF
100.0
µF 0.1µF
±(5.0%rdg +5dgt)
Temperature with type K probe (Autorange)
Range Resolution
Accuracy
Overload
protection
-20°C ÷ 400°C
0.1°C
±(3.0%rdg + 5°C)
250VDC/ACrms
400°C ÷ 760°C
1°C
-4°F ÷ 752°F
0.1°F
±(3.0%rdg + 9°F)
752F ÷ 1400°F
1°F
See also other documents in the category HT instruments Tools:
- COMBI419 (88 pages)
- COMBIG3 (108 pages)
- EQUITEST5071 (44 pages)
- FULLTEST3 (92 pages)
- GEO416 (116 pages)
- HT12 (4 pages)
- HT14N (12 pages)
- HT154 (13 pages)
- HT155 (68 pages)
- HT20 (5 pages)
- HT20 (6 pages)
- HT204 (8 pages)
- HT2055 (35 pages)
- HT21 (17 pages)
- HT2234N (14 pages)
- HT300 (9 pages)
- HT307 (11 pages)
- HT309 (13 pages)
- HT32 (23 pages)
- HT321 (16 pages)
- HT326 (21 pages)
- HT327 (21 pages)
- HT3301 (16 pages)
- HT3320 (30 pages)
- HT37 (24 pages)
- HT4000 (15 pages)
- HT401 (24 pages)
- HT4010 (76 pages)
- HT4011 (21 pages)
- HT4012 (84 pages)
- HT4014 (23 pages)
- HT4020 (152 pages)
- HT5 (12 pages)
- HT5000 (31 pages)
- HT6 (16 pages)
- HT603 (5 pages)
- HT70 (6 pages)
- HT701 (26 pages)
- HT7052 (120 pages)
- HT712 (17 pages)
- HT77N (14 pages)
- HT78 (16 pages)
- HT8000 (16 pages)
- HT8051 (74 pages)