PECIFICATIONS

Method of Detection

Electrochemical Cell

Electrical Classification

CSA-NRTL (US OSHA) approved* Class 1; Groups B, C, D; Div. 1.

Field Wiring

2 conductor; max 10 ohms single conductor resistance

Input Voltage

11.5-28 VDC

Power Consumption

Normal operation = 4 mA (0.1 watts @ 24VDC); Maximum = 20 mA (0.5 watts @ 24VDC; 0.23 watts @ 11.5VDC)

Output

Linear 4-20 mA DC

Repeatability

± 2% FS

Response

Temperature

Temperature

Humidity

Sensor Cell

Model Number

Gas Name

Time(seconds)

Span Drift

Range °C

Range °F

Range %

Warranty

DM-400IS-C2H3O

Acetyldehyde

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C2H2

Acetylene

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C3H3N

Acrylonitrile

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-NH3 (-20°C)

Ammonia

T90 <60

<1% signal loss/month

-20 to +40

-4 to +104

10 to 95

2 years

DM-401IS-NH3 (-40°C)

Ammonia

T90 <90

<2% signal loss/month

-40 to +40

-40 to +104

5 to 95

2 years

DM-402IS-NH3 (CE)

Ammonia

T90 <90

<2% signal loss/month

-40 to +50

-40 to +122

15 to 90

2 years

DM-400IS-AsH3

Arsine

T90 <60

<5% signal loss/month

-20 to +40

-4 to +104

20 to 95

1 1/2 years

DM-400IS-Br2

Bromine

T90 <60

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C4H6

Butadiene

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-CS2

Carbon Disulfide

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-CO

Carbon Monoxide

T90

30

<5% signal loss/year

-40 to +50

-40 to +122

15 to 90

3 years

DM-400IS-COS

Carbonyl Sulfide

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-CL2

Chlorine

T90 <60

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-CLO2 (>10ppm)

Chlorine Dioxide

T90 <60

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-401IS-CLO2 (

10ppm)

Chlorine Dioxide

T90 <120

<1% signal loss/month

-20 to +40

-4 to +104

10 to 95

2 years

DM-400IS-B2H6

Diborane

T90 <60

<5% signal loss/month

-20 to +40

-4 to +104

20 to 95

1 1/2 years

DM-400IS-C2H6S

Dimethyl Sulfide

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C3H5OCL

Epichlorohydrin

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C2H5OH

Ethanol

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C2H5SH

Ethyl Mercaptan

T90 <45

<2% signal loss/month

-40 to +50

-40 to +122

15 to 90

2 years

DM-400IS-C2H4

Ethylene

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C2H4O

Ethylene Oxide

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-F2

Fluorine

T90 <80

<5% signal loss/year

-10 to +40

+14 to +104

10 to 95

1 1/2 years

DM-400IS-CH2O

Formaldehyde

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-GeH4

Germane

T90 <60

<1% signal loss/month

-20 to +40

-4 to +104

20 to 95

1 1/2 years

DM-400IS-N2H4

Hydrazine

T90 <120

<5% signal loss/month

-10 to +40

+14 to +104

10 to 95

1 year

DM-400IS-H2 (ppm)

Hydrogen

T90

30

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-401IS-H2 (LEL)*

Hydrogen

T90 <60

<2% signal loss/month

-40 to +40

-40 to +104

5 to 95

2 years

DM-400IS-HBr

Hydrogen Bromide

T90 <70

<3% signal loss/month

-20 to +40

-4 to +104

10 to 95

1 1/2 years

DM-400IS-HCL

Hydrogen Chloride

T90 <70

<2% signal loss/month

-20 to +40

-4 to +104

10 to 95

1 1/2 years

DM-400IS-HCN

Hydrogen Cyanide

T90 <40

<5% signal loss/month

-40 to +40

-40 to +104

5 to 95

2 years

DM-400IS-HF

Hydrogen Flouride

T90 <90

<10% signal loss/month

-20 to +35

-4 to +95

10 to 80

1 1/2 years

DM-400IS-H2S

Hydrogen Sulfide

T90

30

<2% signal loss/month

-40 to +50

-40 to +122

15 to 90

2 years

DM-400IS-CH3OH

Methanol

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-CH3SH

Methyl Mercaptan

T90 <45

<2% signal loss/month

-40 to +50

-40 to +122

15 to 90

2 years

DM-400IS-NO

Nitric Oxide

T90

10

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

3 years

DM-400IS-NO2

Nitrogen Dioxide

T90 <40

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-O3

Ozone

T90 <120

<1% signal loss/month

-10 to +40

+14 to +104

10 to 95

2 years

DM-400IS-COCL2

Phosgene

T90 <120

<1% signal loss/month

-20 to +40

-4 to +104

10 to 95

1 1/2 years

DM-400IS-PH3

Phosphine

T90 <30

<1% signal loss/month

-20 to +40

-4 to +104

20 to 95

1 1/2 years

DM-400IS-SiH4

Silane

T90 <60

<1% signal loss/month

-20 to +40

-4 to +104

20 to 95

1 1/2 years

DM-400IS-SO2

Sulfur Dioxide

T90

20

<2% signal loss/month

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C4H8S

Tetrahydrothiophene

T90 <30

<2% signal loss/month

-10 to +40

+14 to +104

10 to 95

2 years

DM-400IS-C4H4S

Thiophane

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C6H5CH3

Toluene

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C4H6O2

Vinyl Acetate

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

DM-400IS-C2H3CL

Vinyl Chloride

T90 <140

<5% signal loss/year

-20 to +50

-4 to +122

15 to 90

2 years

* LEL range H2 is not CSA approved.

DM-400IS Toxic Gas Sensors PG.13