beautypg.com

Installation, Figure 3 sstx-mv printed circuit board, 0 installation – Detcon AV2-C1D1M User Manual

Page 7

background image

AV2-C1D1M

AV2-C1D1M Instruction Manual

Rev. 1.5

Page 3 of 8

Figure 3 SSTX-MV printed circuit board

2.0 Installation

The assembly is a T-shaped aluminum bracket with holes pre-drilled to accommodate (2) U-bolt attachments
up to 3”maximum diameter pipe. Overall dimensions are 41.6” H x 29.5” W x 16.625” D.

The tone for the siren is set using tone selector jumpers, J4 & J5. Each jumper consists of three pins and the
selection of appropriate tone is made by placing a jumper on two of the three pins as shown in Figure 3.

The alarm comes pre-wired for the appropriate voltage as ordered from the factory. Customer wiring is
installed through opening at bottom of lower junction box. Connect wiring in accordance with the wiring
diagrams in Figure 5 or Figure 6. Use only 12 to 18 AWG wire for power connections. Strip no more than
0.25-inch of insulation from the ends of the power leads.