beautypg.com

Lifting guidelines (plate), Type of surface condition, O.s. walker inc., cer lift magnet – Walker Magnetics CER SERIES User Manual

Page 14

background image

14

O.S. Walker Inc., CER Lift Magnet

LIFTING GUIDELINES (PLATE)

CER-12, CER-16, and CER-20 (plate)

MAGNET

MODELS

LOAD

THICK-

NESS

TYPE OF SURFACE CONDITION

CLEAN & SMOOTH

Similar to a Flat

(32 micro-inch RMS)

Ground Surface

.000” Max. Air Gap †

RUST OR SCALE

Similar to a Flat Hot

Rolled

Steel Surface

.010” Max. Air Gap †

(.254mm)

IRREGULAR OR ROUGH

Similar to a Flat Smooth

Cut File

.020” Max. Air Gap †

(.508mm)

Max. Load

(lbs.)

Max. Size

(ft.)

Max. Load

(lbs.)

Max. Size

(ft.)

Max. Load

(lbs.)

Max. Size

(ft.)

CER-12

NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 10 FEET

Over 2”

4000

-

3850

-

3475

-

*2”

4000

7 x 7

3850

6 x 7

3475

6 x 7

*1-1/2”

3500

7 x 8

3250

7 x 7

3000

7 x 7

*1”

2800

8 x 8

2600

7 x 8

2300

7 x 8

*3/4”

2100

8 x 8

2000

8 x 8

1900

7 x 8

*1/2”

1100

7 x 7

1050

7 x 7

1000

7 x 7

*3/8”

600

6 x 6

550

6 x 6

500

5 x 6

*1/4”

300

5 x 5

250

4 x 5

200

4 x 4

CER-16

NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 12 FEET

Over 2-1/2”

7250

-

6750

-

6250

-

*2-1/2”

7250

8 x 8

6750

8 x 8

6250

7 x 8

*2”

6000

8 x 9

5500

8 x 8

5000

7 x 8

*1-1/2”

5000

9 x 9

4600

8 x 9

4300

8 x 8

*1”

4000

9 x 10

3750

9 x 10

3500

8 x 9

*3/4”

2500

9 x 9

2300

8 x 9

2200

8 x 8

*1/2”

1300

7 x 8

1200

7 x 8

1100

7 x 7

*3/8”

750

7 x 7

700

6 x 7

600

6 x 6

*1/4”

350

5 x 6

300

5 x 5

250

4 x 5

CER-20

NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 15 FEE

Over 2-1/2”

10500

-

9800

-

9200

-

*2-1/2”

10500

10 x 11

9800

10 x 10

9200

10 x 10

*2”

10000

11 x 11

9500

10 x 11

9000

10 x 11

*1-1/2”

8000

11 x 12

7600

11 x 11

7200

10 x 11

*1”

5500

11 x 12

5200

11 x 11

5000

10 x 11

*3/4”

3000

10 x 10

2800

9 x 10

2600

9 x 9

*1/2”

1500

8 x 9

1400

8 x 8

1300

7 x 8

* LIFTING CAPACITY AFFECTED BY PEEL AND THICKNESS. SEE NOTES 1 & 4 OF THE “IMPORTANT FACTS” (PAGE 6 & 7) IN THIS INSTRUC-

TION MANUAL.

† SEE NOTE 6 OF THE “IMPORTANT FACTS” (PAGE 7) IN THIS INSTRUCTION MANUAL. ALSO READ RECOMMENDED LIFTING PROCEDURES
(PAGE 10).

Values shown are for maximum rated capacities when operating instructions and warnings are followed.

Values are based upon SAE 1020.

Higher alloy steels and other magnetic materials will require further reductions of these rated capacities.

(See Guidelines for the Reduction of Rated Lifting Capacity page 11.)