Lifting guidelines (plate), Type of surface condition, O.s. walker inc., cer lift magnet – Walker Magnetics CER SERIES User Manual
Page 14
14
O.S. Walker Inc., CER Lift Magnet
LIFTING GUIDELINES (PLATE)
CER-12, CER-16, and CER-20 (plate)
MAGNET
MODELS
LOAD
THICK-
NESS
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000” Max. Air Gap †
RUST OR SCALE
Similar to a Flat Hot
Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Max. Load
(lbs.)
Max. Size
(ft.)
Max. Load
(lbs.)
Max. Size
(ft.)
Max. Load
(lbs.)
Max. Size
(ft.)
CER-12
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 10 FEET
Over 2”
4000
-
3850
-
3475
-
*2”
4000
7 x 7
3850
6 x 7
3475
6 x 7
*1-1/2”
3500
7 x 8
3250
7 x 7
3000
7 x 7
*1”
2800
8 x 8
2600
7 x 8
2300
7 x 8
*3/4”
2100
8 x 8
2000
8 x 8
1900
7 x 8
*1/2”
1100
7 x 7
1050
7 x 7
1000
7 x 7
*3/8”
600
6 x 6
550
6 x 6
500
5 x 6
*1/4”
300
5 x 5
250
4 x 5
200
4 x 4
CER-16
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 12 FEET
Over 2-1/2”
7250
-
6750
-
6250
-
*2-1/2”
7250
8 x 8
6750
8 x 8
6250
7 x 8
*2”
6000
8 x 9
5500
8 x 8
5000
7 x 8
*1-1/2”
5000
9 x 9
4600
8 x 9
4300
8 x 8
*1”
4000
9 x 10
3750
9 x 10
3500
8 x 9
*3/4”
2500
9 x 9
2300
8 x 9
2200
8 x 8
*1/2”
1300
7 x 8
1200
7 x 8
1100
7 x 7
*3/8”
750
7 x 7
700
6 x 7
600
6 x 6
*1/4”
350
5 x 6
300
5 x 5
250
4 x 5
CER-20
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER THAN 15 FEE
Over 2-1/2”
10500
-
9800
-
9200
-
*2-1/2”
10500
10 x 11
9800
10 x 10
9200
10 x 10
*2”
10000
11 x 11
9500
10 x 11
9000
10 x 11
*1-1/2”
8000
11 x 12
7600
11 x 11
7200
10 x 11
*1”
5500
11 x 12
5200
11 x 11
5000
10 x 11
*3/4”
3000
10 x 10
2800
9 x 10
2600
9 x 9
*1/2”
1500
8 x 9
1400
8 x 8
1300
7 x 8
* LIFTING CAPACITY AFFECTED BY PEEL AND THICKNESS. SEE NOTES 1 & 4 OF THE “IMPORTANT FACTS” (PAGE 6 & 7) IN THIS INSTRUC-
TION MANUAL.
† SEE NOTE 6 OF THE “IMPORTANT FACTS” (PAGE 7) IN THIS INSTRUCTION MANUAL. ALSO READ RECOMMENDED LIFTING PROCEDURES
(PAGE 10).
Values shown are for maximum rated capacities when operating instructions and warnings are followed.
Values are based upon SAE 1020.
Higher alloy steels and other magnetic materials will require further reductions of these rated capacities.
(See Guidelines for the Reduction of Rated Lifting Capacity page 11.)