Rate check - rate check calculations – Seed Hawk LOUP III & VIPER PRO 2015 - Hydraulic Drive Calibration Guide User Manual
Page 40
![background image](/manuals/364497/40/background.png)
SEED HAWK
®
2015 LOUP III & VIPER PRO™ HYDRAULIC DRIVE CALIBRATION GUIDE
35
22
Actual Rate (lb/ac.)
Correction Factor
x Cal. Weight = New Cal. Weight
=
=
=
x
=
=
Weight of Product Used
Actual Rate
Acres Applied
Target Rate
1 160
145
3.5
1.074
3.76 lb/rev
145 lb/ac.
1.074
8
135
Correction
Factor
The calculations presented here are to demonstrate
how to properly calculate and adjust the metering
rates, once a test area has been seeded.
Target Rate: 135 lb/ac.
Cal. Weight: 3.5 lb/rev
Acres Applied: 8 acres
Weight of Product Used: 1 160 lbs.
Rate Check - Rate Check Calculations