Target Rate

1 160

145

3.5

1.074

3.76 lb/rev

145 lb/ac.

1.074

8

135

Correction

Factor

The calculations presented here are to demonstrate
how to properly calculate and adjust the metering
rates, once a test area has been seeded.

Target Rate: 135 lb/ac.
Cal. Weight: 3.5 lb/rev
Acres Applied: 8 acres
Weight of Product Used: 1 160 lbs.