beautypg.com

Warning, External inspection & cleaning of the flame-trap, Cleaning the combustion chamber and flame-trap – American Water Heater 318935-003 User Manual

Page 26: Replacing the burner door assembly

background image

26

Pilot

Thermopile

Pilot/Thermopile
Assembly

Pilot Tube
(Ferrule Nut
Not Shown)

Igniter
Connector

Thermopile
Connectors

Figure 28

Pilot/Thermopile Assembly
(50K Models)

6. Push the new pilot/thermopile assembly connectors

through the opening in the burner door (See Figure 27).
Do not to scrape or nick the wires during installation.
IMPORTANT: DO NOT USE PILOT/THERMOPILES
WITH FIBERGLASS SLEEVES. The replacement kit
does not contain a fiberglass sleeve over the pilot/
thermopile wires.

7. Attach the pilot assembly to the Burner Door Assembly.
8. Position the new thermopile wires through the top

opening of the manifold component block (Figure 27).
Be sure that the igniter wire is positioned through the
middle opening of the manifold component block.
Position the pilot tube through the bottom opening of
the manifold component block.

9. See “Replacing the Burner Door Assembly” section.

NOTE: Use the ferrule nut supplied with the new pilot/
thermopile assembly when connecting the pilot tube to
the gas control valve/thermostat.

External Inspection & Cleaning of the
Flame-trap

Although not likely to occur, if debris collects on the flame-
trap, use a vacuum, compressed air, or a soft bristle brush
to remove it.
NOTE: If unable to inspect or clean the flame trap from
underneath, follow the “Cleaning the Combustion Chamber
and Flame-trap” section instructions.

Figure 29
Flame-trap visual inspection

Mirror

Flashlight

Cleaning the Combustion Chamber and

Flame-trap

1. Follow procedure outlined in “Removing the Burner

Door Assembly”.

2. Use a vacuum cleaner/shop vac to remove all loose

debris in the combustion chamber (Figure 30A). Use
compressed air to clear any dust or debris that may
have accumulated in the flame-trap.

3. Reassemble following the procedure under “Replacing

the Burner Door Assembly”.

Replacing the Burner Door Assembly

result in death, explosion, or fire.

WARNING

Replace manifold component block if missing

or removed.

Replace door gasket if damaged.

Failure to follow these instructions can

Replace viewport if glass is missing or

damaged.

Tighten both burner door screws
securely.

Explosion Hazard

Remove any fiberglass between gasket

and combustion chamber.

1. Check the door gasket for damage or imbedded debris

prior to installation.

2. Inspect the viewport for damage and replace as required.
3. Insert the burner assembly into the burner

compartment, making sure that the burner assembly
sits firmly against the burner bracket inside the
combustion chamber (Figure 30B).
IMPORTANT: Do not to scrape or nick the wires during
installation.

4. Inspect the door gasket and make sure there is no

fiberglass insulation between the gasket and the
combustion chamber.

5. Replace the two screws which secure the burner

assembly to the combustion chamber and tighten
securely. There should be no space between the
gasket part of the burner door and combustion
chamber. IMPORTANT: Do not operate the water heater