Maintenance of your water heater, Warning, Draining and flushing – American Water Heater 318935-003 User Manual
Page 23: Routine preventative maintenance, Temperature and pressure relief valve
23
MAINTENANCE OF YOUR WATER HEATER
Draining and Flushing
It is recommended that the tank be drained and flushed
every 6 months to remove sediment which may build up
during operation. The water heater should be drained if
being shut down during freezing temperatures. To drain the
tank, perform the following steps:
1. Turn off the gas to the water heater at the manual gas
shut-off valve.
2. Open a nearby hot water faucet until the water is no
longer hot.
3. Close the cold water inlet valve.
4. Connect a hose to the drain valve and terminate it to an
adequate drain or external to the building.
5. Open the water heater drain valve and allow all of the
water to drain from the tank. Flush the tank with water
as needed to remove sediment.
6. Close the drain valve, refill the tank, and restart the
heater as directed in this manual.
If the water heater is going to be shut down for an extended
period, the drain valve should be left open.
IMPORTANT: Condensation may occur when refilling the
tank and should not be confused with a tank leak.
Routine Preventative
Maintenance
At least annually, a visual inspection should be made of
the venting and air supply system, piping systems, main
burner, pilot burner, and Flame-trap. Check the water
heater for the following:
•
Obstructions, damage, or deterioration in the venting
system. Make sure the ventilation and combustion air
supplies are not obstructed.
•
Build up of soot and carbon on the main burner and
pilot burner. Check for a soft blue flame.
•
Leaking or damaged water and gas piping.
•
Presence of flammable or corrosive materials in the
installation area.
•
Presence of combustible materials near the water
heater.
•
After servicing this water heater, check to make sure it
is working properly. (See Operating Your Water Heater
section of this manual.)
IMPORTANT: If you lack the necessary skills required to
properly perform this visual inspection, you should not
proceed, but get help from a qualified person.
Temperature and Pressure
Relief Valve
Manually operate
the temperature
and pressure relief
valve at least once
a year to make
sure it is working
properly. To prevent
water damage,
the valve must be
properly connected
to a discharge line
which terminates
at an adequate
drain. Standing clear of the outlet (discharged water may
be hot), slowly lift and release the lever handle on the
temperature and pressure relief valve to allow the valve to
operate freely and return to its closed position. If the valve
fails to completely reset and continues to release water,
immediately shut off the manual gas control valve and the
cold water inlet valve and call a qualified person.
Figure 21
Temperature and Pressure
Relief Valve
Manual Relief
Valve
Discharge line to drain
Explosion Hazard
If the temperature and pressure relief valve
is dripping or leaking, have a qualified
person replace it.
Examples of a qualified person include:
licensed plumbers, authorized gas company
personnel, and authorized service
personnel.
Do not plug valve.
Do not remove valve.
Failure to follow these instructions can
result in death, or explosion.
WARNING