SANDPIPER M10 Non-Metallic User Manual
Page 20
M10nmdl1sm-rev0513
Models M10 Non-Metallic Page 18
Pilot Valve Servicing, Assembly Drawing & Parts List
PILOT VALVE ASSEMBLY PARTS LIST
ITEM PART NUMBER
DESCRIPTION
QTY
3
095-091-000
Pilot Valve Assembly
1
3-A
095-087-551
Valve Body
1
3-B
755-051-000
Sleeve (With O-rings)
1
3-C
560-033-379
O-ring (Sleeve)
6
3-D
775-055-000
Spool (With O-rings)
1
3-E
560-023-379
O-ring (Spool)
3
3-F
675-037-080
Retaining Ring
1
PILOT VALVE SERVICING
To service the pilot valve first shut
off the compressed air supply, bleed
the pressure from the pump, and
disconnect the air supply line from the
pump.
STEP #1: See pump assembly
drawing.
Using a 7/16" wrench or socket,
remove the four capscrews (item 12).
Remove the air inlet cap (item 8) and
air inlet gasket (item 18). The pilot valve
assembly (item 3) can now be removed
for inspection and service.
STEP #2: Disassembly of the pilot
valve.
Remove the pilot valve spool (item
3-D). Wipe clean and inspect spool and
o-rings for dirt, cuts or wear. Replace
the o-rings and spool if necessary.
Remove the retaining ring (item
3-F) from the end of the sleeve (item
3-b) and remove the sleeve from the
valve body (item 3-A). Wipe clean and
inspect sleeve and o-rings for dirt, cuts
or wear. Replace the o-rings and sleeve
if necessary.
STEP #3: Re-assembly of the pilot
valve.
Generously lubricate outside
diameter of the sleeve and o-rings.
Then carefully insert sleeve into valve
body. Take CAUTION when inserting
sleeve, not to shear any o-rings. Install
retaining ring to sleeve. Generously
lubricate outside diameter of spool and
o-rings. Then carefully insert spool into
sleeve. Take CAUTION when inserting
spool, not to shear any o-rings. Use
BP-LS-EP-2 multipurpose grease,
or equivalent.
STEP #4: Re-install the pilot valve
assembly into the intermediate.
Be careful to align the ends of the
pilot valve stem between the plunger
pins when inserting the pilot valve into
the cavity of the intermediate.
Re-install the gasket, air inlet cap
and capscrews. Connect the air supply
to the pump. The pump is now ready
for operation.