beautypg.com

SANDPIPER M10 Non-Metallic User Manual

Page 20

background image

M10nmdl1sm-rev0513

Models M10 Non-Metallic Page 18

Pilot Valve Servicing, Assembly Drawing & Parts List

PILOT VALVE ASSEMBLY PARTS LIST

ITEM PART NUMBER

DESCRIPTION

QTY

3

095-091-000

Pilot Valve Assembly

1

3-A

095-087-551

Valve Body

1

3-B

755-051-000

Sleeve (With O-rings)

1

3-C

560-033-379

O-ring (Sleeve)

6

3-D

775-055-000

Spool (With O-rings)

1

3-E

560-023-379

O-ring (Spool)

3

3-F

675-037-080

Retaining Ring

1

PILOT VALVE SERVICING

To service the pilot valve first shut

off the compressed air supply, bleed

the pressure from the pump, and

disconnect the air supply line from the

pump.

STEP #1: See pump assembly

drawing.

Using a 7/16" wrench or socket,

remove the four capscrews (item 12).

Remove the air inlet cap (item 8) and

air inlet gasket (item 18). The pilot valve

assembly (item 3) can now be removed

for inspection and service.

STEP #2: Disassembly of the pilot

valve.

Remove the pilot valve spool (item

3-D). Wipe clean and inspect spool and

o-rings for dirt, cuts or wear. Replace

the o-rings and spool if necessary.

Remove the retaining ring (item

3-F) from the end of the sleeve (item

3-b) and remove the sleeve from the

valve body (item 3-A). Wipe clean and

inspect sleeve and o-rings for dirt, cuts

or wear. Replace the o-rings and sleeve

if necessary.

STEP #3: Re-assembly of the pilot

valve.

Generously lubricate outside

diameter of the sleeve and o-rings.

Then carefully insert sleeve into valve

body. Take CAUTION when inserting

sleeve, not to shear any o-rings. Install

retaining ring to sleeve. Generously

lubricate outside diameter of spool and

o-rings. Then carefully insert spool into

sleeve. Take CAUTION when inserting

spool, not to shear any o-rings. Use

BP-LS-EP-2 multipurpose grease,

or equivalent.

STEP #4: Re-install the pilot valve

assembly into the intermediate.

Be careful to align the ends of the

pilot valve stem between the plunger

pins when inserting the pilot valve into

the cavity of the intermediate.

Re-install the gasket, air inlet cap

and capscrews. Connect the air supply

to the pump. The pump is now ready

for operation.