beautypg.com

Important safety information recycling, Warning, Caution – SANDPIPER M10 Non-Metallic User Manual

Page 11: Warning important

background image

M10nmdl1sm-rev0513

Models M10 Non-Metallic Page 9

This pump is pressurized

internally with air pressure

during operation. Always

make certain that all bolting

is in good condition and

that all of the correct

bolting is reinstalled during assembly.

WARNING

Before pump operation,

i n s p e c t a l l g a s k e t e d

fasteners for looseness

caused by gasket creep. Re-

torque loose fasteners to

prevent leakage. Follow recommended torques

stated in this manual.

CAUTION

When used for toxic or

aggressive fluids, the pump

should always be flushed

clean prior to disassembly.

WARNING

B e f o r e m a i n t e n a n c e

or repair, shut off the

compressed air line,

bleed the pressure, and

disconnect the air line from

the pump. The discharge

line may be pressurized and must be bled of

its pressure.

WARNING

IMPORTANT

Read these safety warnings

and instructions in this

manual completely, before

installation and start-up

of the pump. It is the

responsibility of the purchaser to retain this

manual for reference. Failure to comply with

the recommendations stated in this manual will

damage the pump, and void factory warranty.

WARNING

Airborne particles and loud

noise hazards.
Wear ear and eye protection.

WARNING

In the event of diaphragm

rupture, pumped material

may enter the air end of the

pump, and be discharged

into the atmosphere. If

pumping a product which is hazardous or toxic,

the air exhaust must be piped to an appropriate

area for safe disposition.

B e f o r e d o i n g a n y

maintenance on the pump,

be certain all pressure is

completely vented from the

pump, suction, discharge,

piping, and all other openings and connections.

Be certain the air supply is locked out or made

non-operational, so that it cannot be started

while work is being done on the pump. Be

certain that approved eye protection and

protective clothing are worn all times in the

vicinity of the pump. Failure to follow these

recommendations may result in serious injury

or death.

WARNING

Take action to prevent

static sparking. Fire or

explosion can result,

especially when handling

flammable liquids. The

pump, piping, valves, containers or other

miscellaneous equipment must be grounded.

WARNING

Important Safety

Information

Recycling

Many components of MARATHON

®

Metallic AODD pumps are made of

recyclable materials (see chart on

page 9 for material specifications).

We encourage pump users to recycle

worn out parts and pumps whenever

possible, after any hazardous pumped

fluids are thoroughly flushed.

Pump complies with EN809 Pumping Directive, Directive

98/37/EC Safety of Machinery. For reference to the

declarations of conformity visit: www.warrenrupp.com.