beautypg.com

St25, Type 5, Containment duty – SANDPIPER ST25 User Manual

Page 3

background image

st1dl5sm-rev0614

Models ST1 & ST25 Page 1

INTAKE/DISCHARGE PIPE SIZE

ST1: 1” NPT (internal)

ST25: 1” BSP Tapered (internal)

CAPACITY

0 to 42 gallons per minute

(0 to 159 liters per minute)

AIR VALVE

No-lube, no-stall

design

SOLIDS-HANDLING

Occational solids only,

to nearly .25” (6.3mm)

HEADS UP TO

125 psi or 289 ft. of water

(8.8 Kg/cm

2

or 88 meters)

DISPLACEMENT/STROKE

.09 Gallon / .34 liter

Quality System

ISO9001 Certified

Environmental

Management System

ISO14001 Certified

SANDPIPER

®

pumps are designed to be powered only by compressed air.

Containment Duty

ST1

Type 5

ST25

Type 5

Air-Operated

Double Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

See page 2
for ATEX ratings.

See pages 17 & 18

for ATEX ratings.

100

10(17)

15(25.4)

20(34)

25(42.5)

30(51)

35(59.5)

40(68)

90

80

70
60

50
40

30

20
10

0

0

4

8

12

16

20

24

28

32

36

40

40 PSI

60 PSI

80 PSI

100 PSI

45(76.5)

50(85)

0

20

40

60

80

100

120

140

150

0

1

2

3

4

5

6

7

PSI

BAR

20 PSI Air Inlet Pressure

US Gallons per minute

Liters per minute

CAPACITY

HEAD

AIR CONSUMPTION

SCFM (M

3

/hr)

MODEL ST1/ST25 Performance Curve

Performance based on the following: elastomer fitted pump, flooded suction,

water at ambient conditions. The use of other materials and varying hydraulic

conditions may result in deviations in excess of 5%.

SANDPIPER® Containment Duty Pumps: Sealless Safety

This pump is part of the Containment Duty Pumps. It is specially fitted with PTFE diaphragms as well as elastomeric or elastomeric/PTFE driver diaphragms. The liquid-filled

spill chambers provide an additional chemically-resistant barrier, should a pumping diaphragm fail. The Spill Containment design gives the pump user advanced warning of

diaphragm failure, before pumpage can damage the air valve or be released into the work environment. Three optional leak detectors available for this model:

• Mechanical VIP Leak Detector* 031-025-000

• Electronic Leak Detector* (115V) 032-043-000

• Electronic Leak Detector* (220V) 032-043-000

The Containment Duty pumps offer many different levels of materials and spill monitoring devices designed to fit a variety of applications and budgets.

* Leak Detectors are not ATEX Compliant

This manual is related to the following products: