C. Low flow rate and slow cycling rate indicate restricted flow through the discharge line.

Low flow rate and fast cycling rate indicate restriction in the suction line or air leakage

into suction.

D. Unstable cycling indicates improper check valve seating on one chamber. This

condition is confirmed when unstable cycling repeats consistently on alternate exhausts.

Cycling that is not consistently unstable may indicate partial exhaust restriction due

to freezing and thawing of exhaust air. Use of an anti-freeze lubricant in an air line

lubricator should solve this problem.

E. Incorrect driver fluid level or unpurged air in the chamber can cause poor

performance.

For additional information, see the Warren Rupp Troubleshooting Guide.

WARRANTY

This pump is warranted for a period of five years against defective material and

workmanship. Failure to comply with the recommendations stated in this manual voids

all factory warranty.