D-1
TROUBLESHOOTING
D-1
X-TRACTOR 1GC
Observe all Safety Guidelines detailed througout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Poor Suction
Motor not Running in Auto or Manual
Will not sense current
Cover will not fasten to case
Leakage
Filter too dirty
Improper application
Filter blocked
Brushes worn in one of the motors
Brushes worn
Circuit breaker tripped
Operating current too low
Current sensor or P.C. board dam-
aged
Fasteners not lined up
Check: Hose connections, Hose integrity
Clean the filter, check for oily conditions
Check: Hose dia. & length; Check filter
for oily conditions
Replace filter
Replace brushes in both motors
Check brushes, replace if worn
Reset circuit breaker (See Electrical
Maintenance)
Loop cable in hook two or three times
Replace sensor or P.C. board
Check procedure in “Emptying the
Canister and Heavy Particle Trap” (Step
7)