Maintenance, Replacing the filter, Warning – Lincoln Electric IM576 X-TRACTOR 1GC User Manual
Page 12: Releasing and fastening the case front

C-2
MAINTENANCE
C-2
REPLACING THE FILTER
The filter is a long life, polyester filter designed to be
repeatedly cleaned by compressed air. Therefore, it
should need replacement only after an extended peri-
od of time. Certain applications can reduce this peri-
od, especially very oily smoke or excessive moisture.
Replacement is necessary when, after several clean-
ing cycles, the suction performance of the system is
still lower than normal or due to mechanical damage
to the filter. Overall filter life depends on a great num-
ber of variables such as type of fume, duty cycle,
operating factor, capture efficiency, etc.
The particulate matter collected in the canister
may be dangerous to your health. Take necessary
precautions so that you and your fellow workers
do not breathe the dust and particulate. Wear a
suitable respirator when disposing of the particu-
late.
Check with local authorities for regulations gov-
erning the disposal of used filters.
------------------------------------------------------------------------
1. Clean the filter and empty the canister and heavy
particle trap.
2. Before replacing the canister, loosen the bolts from
the bottom of the canister using an adjustable
wrench. Rotate the filter until it is unhooked from
the bolts.
3. Remove the filter and replace with a new one.
4. Tighten the bolts and replace the canister into the
machine.
X-TRACTOR 1GC
WARNING
FIGURE 1
CLOSED POSITION
CLOSED POSITION
OPEN POSITION
OPEN POSITION
(TWO INSIDE HOLD
COVER TO CASE)
(FOUR CORNERS HOLD
FILTER CONTAINER TO CASE)
Releasing and Fastening the Case Front:
The quick fasteners release with a 1/4 turn, and snap
in place when properly aligned.
Opening: 1) Turn 1/4-turn from closed position until a
“click” is heard.
Closing: 1) Place the cover in the correct position.
2) Turn the fasteners to closed position and
push until a “click” is heard.