beautypg.com

Troubleshooting, Caution – Lincoln Electric IM625 Statiflex 200-M K1654-1 User Manual

Page 13

background image

D-1

TROUBLESHOOTING

D-1

STATIFLEX 200-M

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

SYMPTOM

PROBLEM

SOLUTION

Poor suction.

Dust or smoke coming out of outlet.

Refer to SF2400 Stationary Fan, and
appropriate arm manual for more
troubleshooting.

Leakage.

Outlet blocked.

Air path in arm blocked.

Filter blocked (check Maintenance
Indicator).

Spark arrester blocked.

Blower fan blocked.

Fan seal damaged.

Filter damaged, or not seated cor-
rectly.

Check hose connections and integrity

Remove obstructions from outlet grid.

Remove obstructions from arm.

Replace filter.

Clean the spark arrester.

Clean excess fume or spatter from fan.

Check or replace sealing material of fan.

Replace the filter or reseat it.