E-5

TROUBLESHOOTING

SA-250

E-5

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

With Idler Control Switch in the Auto Position,

Engine Will Not Return to Low Idle in Approximately 15 Seconds

After Welding and Auxiliary Loads are Removed

Set Idler Control Switch

to the Auto Position

Check for Continuity through Idler

Control Switch

Open

Closed

Measure DC Voltage on

Replace Idler

Idler Solenoid Coil

Control Switch

12 VDC

0 VDC

Check Continuity of

Check for Jamming

Reed Switch in Weld Circuit

of the Idler Solenoid

Mechanism or a broken

Return Spring

Open

Closed

1. Check Wiring in

Replace Reed

Idler Solenoid

Switch

Circuit

2. Replace Idler

P.C. Board

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.