Operation, Caution, Safety precautions – Lincoln Electric IM754 RED-D-ARC ZR-10 User Manual

Page 14

background image

B-1

OPERATION

ZR-10

B-1

Welder Controls - Function and Operation

ENGINE

ON-OFF

Switch

When placed in the “ON” position, this switch
energizes the engine ignition circuit. When placed in
the “OFF” position, the ignition circuit is de-energized
to shut down the engine.

ENGINE

START

Push-Button Switch

Energizes engine starter motor.

Polarity

Switch

Never change the

Polarity

switch setting while

welding. This will damage the switch.

Range

Switch

Never change the

RANGE

Switch setting while

welding. This will damage the switch.

ON

OFF

Explanation of Symbols that Appear on this Equipment

Low Idle

High Idle

CAUTION

STICK/TIG - CC

50, 70, 90

6 Range Settings 125, 175, 210 DC/225 AC

WIRE FEED - CV
1 Range Setting 200

Process

Maximum Current

CAUTION

GENERAL DESCRIPTION

The ZR-10 is a twin-cylinder, gasoline driven, multi-
process arc welder and AC power generator. It is built
in a heavy gauge steel case for durability on the job
site.

SAFETY PRECAUTIONS

Read and understand this entire section before
operating your ZR-10.
Do not attempt to use this equipment until you
have thoroughly read all operating and mainte-
nance manuals supplied with your machine. They
include important safety precautions, detailed
engine starting, operating and maintenance
instructions and parts lists.

ELECTRIC SHOCK can kill.

Do not touch electrically live parts
such as output terminals or internal
wiring.

Insulate yourself from the work and
ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

Use in open, well ventilated areas or
vent exhaust outside

Do not stack anything near the
engine.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or
guards off.

Stop engine before servicing.

Keep away from moving parts

------------------------------------------------------------------------

Only qualified personnel should operate this

equipment.

ADDITIONAL SAFETY PRECAUTIONS

Always operate the welder with the hinged door
closed and the side panels in place as these pro-
vide maximum protection from moving parts and
insure proper cooling air flow.

WELDER OUTPUT

• Maximum Open Circuit Voltage at 3700 RPM is

80 Volts RMS.

• Duty Cycle: 100% for both welding and auxiliary

power.

ZR-10

Constant Current

225 Amps AC @ 25 Volts
210 Amps DC @ 25 Volts

Constant Voltage

200 Amps DC @ 20 Volts