OPERATION

B-9

RANGER 8+ DIESEL

AUXILIARY POWER

The RANGER 8+ DIESEL can provide up to 9,000
watts of 115/230 volts AC, Single phase 60 HZ power
for continuous use. The front of the machine includes
three receptacles for connecting AC power Plugs, one
50 amp 115/230 volt NEMA 14-50R receptacle and
two 15 amp 115 volt NEMA 5-15R receptacles. Do
not connect any plugs that connect to the power
receptacles in parallel.

Start the engine and set the "IDLER" control switch to
the desired operating mode. Set the "CONTROL" to
10. Voltage is now correct at the receptacles for auxil-
iary power.

Most 1.5 hp AC single phase motors can be started if
there is no load on the motor or other load connected
to the machine. Larger motors through 2 hp can be
run provided the receptacle rating as previously stated

is not exceeded. This may necessitate 230 volt oper-
ation only.

SIMULTANEOUS WELDING AND POWER
LOADS

Auxiliary power ratings are with no welding load.
Simultaneous welding and power loads are permitted
by the following table. The permissible currents
shown assume that current is being drawn from either
the 115 volt or 230 volt supply (not both at the same
time).

Output

Selector

Setting

Welding

Output

Amps

Permissible

Power Watts

(Unity Power

Factor)

Permissible

Auxiliary Current in

Amperes @ 115V

Permissible

Auxiliary Current

in Amperes @

230V

0

10

16

21

23

26

40

0

20

32

42

46

52

80

NONE

2100

3800

5000

5600

6300

9000

225 DC / 250 AC

175

125

90

70

50

MAX

175

125

90

70

50

NO WELDING

RANGER 8+ DIESEL SIMULTANEOUS WELDING AND POWER LOADS

(OUTPUT CONTROL SET AT 10)

TABLE B.4

NOTE: Voltage and permissible watts decrease as "CONTROL" is adjusted to settings less than 10. It is recommended that

at settings less than 10, only incandescent lighting loads be connected to the auxiliary power receptacles.