beautypg.com

Operation, Warning – Lincoln Electric IM752 RANGER 8 User Manual

Page 20

background image

B-3

OPERATION

B-3

STARTING/SHUTDOWN INSTRUCTIONS

STARTING THE ENGINE

Be sure all Pre-Operation Maintenance has been per-
formed. Also, read the Engine Owner

s Manual.

Remove all loads connected to the AC power recepta-
cles. To start the engine, set the

Idler Control

switch

in the Automatic ( / ) position.

Use the choke control as follows:

ONAN ENGINE - If the engine is cold, pull the choke
control out. Do not use the choke if the engine is
warm or hot.

KOHLER ENGINE - Always pull the choke control out
when starting the engine; cold, warm or hot. Place the

Engine

switch in the

ON

position.

HONDA ENGINE - If the engine is cold, pull the choke
control out. Do not use the choke if the engine is
warm or hot. Place the

Engine

switch in the

ON

position.

Push the

START

button and crank the engine until it

starts. Release the button as soon as the engine
starts. Do not push the

START

button while the

engine is running because this will cause damage to
the ring gear and/or starter motor. After the engine
has started, slowly return the choke control to the full

in

position (choke open).

After running at high engine speed for 10-14 seconds,
the engine will go to low idle.
Allow the engine to warm up by letting it run at low idle
for a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and
allow engine to run at low idle speed for a few minutes
to cool the engine.

Stop the engine by placing the

Engine

switch in the

OFF

position.

A fuel shut off valve is not required on the Ranger 8
because the fuel tank is mounted below the engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount of
oil until the break-in is accomplished. Check the oil
level twice a day during the break-in period (approxi-
mately 50 running hours)).

IMPORTANT: IN ORDER TO ACCOMPLISH THIS

BREAK-IN, THE UNIT SHOULD BE
SUBJECTED TO MODERATE
LOADS, WITHIN THE RATING OF
THE MACHINE. AVOID LONG IDLE
RUNNING PERIODS. REMOVE
LOADS AND ALLOW ENGINE TO
COOL BEFORE SHUTDOWN.

The engine manufacturer

s recommendation for the

running time until the first oil change is as follows:
The oil filter is to be changed at the second oil
change. Refer to the Engine Owner

s Manual for more

information.

RANGER 8

Do not touch electrically live parts

of electrode with skin or wet
clothing.

Keep flammable material away.

Insulate yourself from work and

ground. Wear eye, ear, and body
protection.

Keep your head out of the fumes.

Use ventilation or exhaust to

remove fumes from breathing zone.

WARNING

Honda

GX620KI

First Month

or 20 HRS

Kohler

CH20S

5 HRS

Onan

P220

25 HRS