Pin, lead connector setups – Lincoln Electric IM718 POWER WAVE AC_DC User Manual
Page 40
F-3
PIN, LEAD CONNECTOR SETUPS
F-3
POWER WAVE AC/DC
TABLE F.5 DEVICENET CONNECTOR S5
Pin
Lead #
Function
2
894
+24vdc Devicenet
3
893
Commom Devicenet+
4
892
Devicenet H
5
891
Devicenet L
TABLE F.2 WIRE FEEDER RECEPTACLE S1
Pin
Lead #
Function
A
53
Arclink L
B
54
Arclink H
C
67A
Electrode Voltage Sense
D
52
Ground(0v)
E
51
+40vdc
TABLE F.6 EXTERNAL I/O S7
Pin
Lead #
Function
1
851
+15vdc for Trigger group
2
852
Trigger input
3
853
Dual procedure input
4
854
4 Step input
5
855
+15vdc for cold inch group
6
856
cold inch forward
7
857
cold inch reverse
8
858
gas purge input
9
859
+15vdc for shutdown group
10
860
shutdown1 input
11
861
shutdown2 input
12
862
input B
TABLE F.4 RS232 CONNECTOR S3
Pin
Lead #
Function
2
253
RS232 Receive
3
254
RS232 Transmit
4
#
S3 Pin5
5
#
S3 Pin4
6
##
S3 Pin20
20
##
S3 Pin6
7
251
RS232 Common
TABLE F.3 VOLTAGE SENSE RECEPTACLE S2
Pin
Lead #
Function
3 21A
Work Voltage Sense
Pin
Robotic Interface Connector (S6) Master / Slave Input(S12)
Master / Slave Output(S13)
A
+15vdc Tach voltage
Reserved for future use
Reserved for future use
B
Tach common
Reserved for future use
Reserved for future use
C
Tach 1A differential signal
Sync In
Reserved for future use
D
Tach 1B differential signal
Sync In
Reserved for future use
E
Tach 2A differential signal
Ready In
Ready In
F
Tach 2B differential signal
Ready In
Ready In
G
Single Tach Input
Polarity Out
Polarity Out
H
Reserved for future use
Polarity Out
Polarity Out
I
Voltage sense lead
Ground
J
Motor "+"
Reserved for future use
Reserved for future use
K
Motor "-"
Reserved for future use
Reserved for future use
L
Reserved for future use
+40v (COM)
Reserved for future use
M
Reserved for future use
+40v ("+")
Reserved for future use
N
+40vdc for solenoid
Reserved for future use
Reserved for future use
P
solenoid input
Reserved for future use
Reserved for future use
R
Reserved for future use
Reserved for future use
Reserved for future use
S
Reserved for future use
Reserved for future use
Reserved for future use
T
Shield ground to case
Drain (ethernet)
Drain (ethernet)
U
Reserved for future use
Kill Out
Kill Out
V
Reserved for future use
Kill Out
Kill Out
W
Reserved for future use
Reserved for future use
Reserved for future use
X
Reserved for future use
Reserved for future use
Reserved for future use
Table F.1 INTERFACE CONNECTOR WIRING