Installation – Lincoln Electric IM618 POWER WAVE 455STT User Manual
Page 8

A-1
INSTALLATION
POWER WAVE 455 STT
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE 455 STT (K1518-3)
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT VOLTS
380V - 60HZ.
380V - 50HZ.
415V - 60HZ.
415V - 50HZ.
OPEN
CIRCUIT
VOLTAGE
75 VDC
INPUT
VOLTAGE /
FREQUENCY
380
415
HEIGHT
26.10 in
663 mm
WIDTH
19.86 in
505 mm
DEPTH
32.88 in
835 mm
WEIGHT
267 lbs.
121 kg.
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
40 AMP
40 AMP
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG[IEC] SIZES
(MM2)
10 (6)
10 (6)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG[IEC] SIZES
(MM2)
8 (10)
8 (10)
INPUT AMPERE
RATING ON
NAMEPLATE
36
33
DUTY
CYCLE
100%
100%
PROCESS CURRENT RANGES (DC)
MIG/MAG
FCAW
SMAW
Pulse
STT
CURRENT
50-500 Amps
40-500 Amps
30-500 Amps
5-750 Amps
40-325 Amps
PULSE
VOLTAGE
RANGE
5 - 55 VDC
AUXILIARY
POWER
40 VDC AT
10 AMPS
220 VAC AT
5 AMPS
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC.
-
3.3 SEC.
STT PARAMETERS
PEAK & BACK-
GROUND CURRENT
15-450 AMPS
CURRENT
RANGE
5 - 570
PULSE
FREQUENCY
0.15 - 1000 Hz
INPUT
CURRENT
36
36
33
33
INPUT
CURRENT
48
48
44
44
OUTPUT CONDITIONS
EXCEPT STT PROCESS
400A@36V. 100%
400A@36V. 100%
400A@36V. 100%
400A@36V. 100%
OUTPUT CONDITIONS
STT PROCESS ALL VOLTAGES
325A@33V. 100%
OUTPUT CONDITIONS
EXCEPT STT PROCESS
500A@40V. 60%
500A@40V. 60%
500A@40V. 60%
500A@40V. 60%
OUTPUT CONDITIONS
STT PROCESS ALL VOLTAGES
325A@33V. 100%
OPERATING TEMPERATURE RANGE
0°C to 40°C
STORAGE TEMPERATURE RANGE
-50°C to 85°C