beautypg.com

Operation, Welding capability, Limitations – Lincoln Electric IM618 POWER WAVE 455STT User Manual

Page 16: Compatible lincoln equipment, Power source operation

background image

B-4

OPERATION

POWER WAVE 455 STT

B-4

WELDING CAPABILITY

The POWER WAVE 455 STT is rated at 400A@ 36V,
100% duty cycle or 500A@40V 60% duty cycle. The
machine is capable of higher outputs at lower duty
cycles. For the STT process only, the machine is
rated at 325 amps, 100% duty cycle.

If the duty cycle is exceeded, a thermostat will shut off
the output until the machine cools to a reasonable
operating temperature.

LIMITATIONS

• The Power Wave is not recommended for process-

es other than those listed.

• The Power Wave can only be used with Power

Feed wire feeders. Other models of Lincoln feed-
ers, or any models of non-Lincoln wire feeders, can-
not be used.

COMPATIBLE LINCOLN EQUIPMENT

All Lincoln Power Feed™ Wire Feeders.

POWER SOURCE OPERATION

DUTY CYCLE AND TIME PERIOD

The POWER WAVE 455 STT is rated at 400A@ 36V,
100% duty cycle or 500A@40V 60% duty cycle. The
duty cycle is based upon a ten minute period. For the
STT process only, the machine is rated at 325 amps,
100% duty cycle. A 60% duty cycle represents 6 min-
utes of welding and 4 minutes of idling in a ten minute
period.

CASE FRONT CONTROLS

All operator controls and adjustments are located on
the case front of the Power Wave.

1. POWER SWITCH: Controls input power to the

Power Wave.

2. STATUS LIGHT: A two color light that indicates

system errors. Normal operation is a steady green
light. Error conditions are indicated as follows:

NOTE: The POWER WAVE 455 STT status light will
flash green, and sometimes red and green, for up to
one minute when the POWER WAVE 455 STT is first
turned on. This is a normal situation as the machine
goes through a self test at power up.

3. HIGH TEMPERATURE LIGHT (thermal overload):

A yellow light that comes on when an over temper-
ature situation occurs. Output is disabled until the
machine cools down. When cool, the light goes
out and output is enabled.

4. 10 AMP WIRE FEEDER CIRCUIT BREAKER:

Protects 40 volt DC wire feeder power supply.

5. 5 AMP AUXILIARY POWER CIRCUIT BREAKER:

Protects 220 volt AC case front receptacle auxiliary
supply.

Light

Condition

Steady Green

Blinking
Green

A l t e r n a t i n g
Green and
Red

Steady Red

Blinking Red

Meaning

System OK. Power source communicating nor-
mally with wire feeder and its components.

Nothing connected to Wire Feeder
Receptacle.

Recoverable system fault.See
Troubleshooting Section.

Non-recoverable system fault. Must turn
power source off, find source of error, and
turn power back on to reset. See
Troubleshooting Section.

See Troubleshooting Section.