beautypg.com

Troubleshooting, Caution – Lincoln Electric IM746 POWER WAVE 405 User Manual

Page 34

background image

E-6

TROUBLESHOOTING

E-6

POWER WAVE 405

Observe all Safety Guidelines detailed throughout this manual

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Machine often “noodle welds” (out-
put is limited to approximately 100
amps) when running a particular
procedure, especially a procedure
with high WFS.

Machine won’t produce full output.

Auxiliary receptacle is “dead” no
auxiliary voltage .

1.Secondary current limit has been

exceeded, and the machine has
phased back to protect itself.

2. Adjust procedure or reduce load

to lower current draw from the
machine.

1. Input voltage may be too low,

limiting output capability of the
power source. Make certain that
the input voltage is proper,
according to the Rating Plate
located on the rear of the
machine.

2. Secondary current or voltage not

be properly calibrated. Check
values displayed on the Power
Feed 10/11 verses readings on
an external meter.

1. Circuit breaker CB1 (on case

front) may have opened. Reset.

2. Circuit breaker CB3 (in recon-

nect area) may have opened.
Reset.

If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Lincoln
Authorized Field Service Facility.