Troubleshooting, Caution – Lincoln Electric IM746 POWER WAVE 405 User Manual
Page 34
E-6
TROUBLESHOOTING
E-6
POWER WAVE 405
Observe all Safety Guidelines detailed throughout this manual
TROUBLESHOOTING GUIDE
Observe Safety Guidelines
detailed in the beginning of this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local authorized Lincoln Electric Field Service Facility for technical assistance.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
Machine often “noodle welds” (out-
put is limited to approximately 100
amps) when running a particular
procedure, especially a procedure
with high WFS.
Machine won’t produce full output.
Auxiliary receptacle is “dead” no
auxiliary voltage .
1.Secondary current limit has been
exceeded, and the machine has
phased back to protect itself.
2. Adjust procedure or reduce load
to lower current draw from the
machine.
1. Input voltage may be too low,
limiting output capability of the
power source. Make certain that
the input voltage is proper,
according to the Rating Plate
located on the rear of the
machine.
2. Secondary current or voltage not
be properly calibrated. Check
values displayed on the Power
Feed 10/11 verses readings on
an external meter.
1. Circuit breaker CB1 (on case
front) may have opened. Reset.
2. Circuit breaker CB3 (in recon-
nect area) may have opened.
Reset.
If all recommended possible areas
of misadjustments have been
checked and the problem persists,
contact your local Lincoln
Authorized Field Service Facility.