beautypg.com

Installation, Technical specifications – Lincoln Electric IM745 POWER WAVE 355 User Manual

Page 8

background image

A-1

INSTALLATION

POWER WAVE 355

A-1

TECHNICAL SPECIFICATIONS -

POWER WAVE 355

INPUT AC VOLTAGE & DC OUTPUT

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

(continuous)

200

350A / 34V / 60%

14.8” x 13.3” x

POWER

K2152-1

208-230/

27.8”*

WAVE

380-400/

AMPS

(81.5 lbs.)

(373 x 338 x

355

415-460/

5-425

(37.0 kg.)

706*)mm

575

300A / 32V /100%

1& 3 Phase

* Includes Handles

60/50 Hz

* Overall Length Including Handle, 21.6” (549mm) without handle.

Voltage

200

208
230
380

400

415
460
575

200
208
230
380
400
415
460
575

Phases

1

1
1
1

1

1
1
1

3
3
3
3
3
3
3
3

300Amps @

32Volts(100%)

Not

Recommended

76
69

Not

Recommended

Not

Recommended

41
36
31

41
39
36
23
22
22
19
16

350Amps @

34Volts(60%)

Not

Recommended

94
85

Not

Recommended

Not

Recommended

64
42
37

50
50
42
28
27
26
23
18

Line Cord

AWG

2
4

---

6
8
8

6
6
8
8
8
8
8
8

Fuse size

---

125A
125A

---

---

80A
70A
50A

80A
80A
70A
40A
40A
40A
40A
30A

POWER WAVE 355 INPUT CURRENT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Recommemded Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

100%

60%

CURRENT

300
350

LENGTH UP 200FT. (61m)

2/0
2/0

200-250 FT. (61-76m)

2/0
2/0

Notes

Note 1

Note 2
Note 2
Note 1

Note 1

Note 2

Note 2
Note 2

*

Lincoln Electric recommends using a mimimum of 2/0 welding cable for pulse welding.