beautypg.com

Maintenance, Caution, Warning – Lincoln Electric IM751 POWER-ARC 4000 User Manual

Page 34

background image

D-2

MAINTENANCE

D-2

FUEL: At the end of each day’s use, refill

the fuel tank to minimize moisture conden-
sation and dirt contamination in the fuel line.

ENGINE ADJUSTMENTS

OVERSPEED IS HAZARDOUS - The maximum
allowable high idle speed for this machine is 3750
RPM, no load. DO NOT tamper with the governor
components or setting or make any other adjust-
ments to increase the maximum speed. Severe
personal injury and damage to the machine can
result if operated at speeds above maximum.

------------------------------------------------------------------------

Adjustments to the engine are to be made only by a
Lincoln Service Center or an authorized Field Service
Shop.

Do not use petroleum solvents such as kerosene
to clean the air cleaner. They may cause deterio-
ration of the air cleaner. DO NOT OIL THE AIR
CLEANER OR USE PRESSURIZED AIR TO CLEAN
OR DRY THE AIR CLEANER.

-----------------------------------------------------------

To service the pre-cleaner:

1. Wash in liquid detergent and water.

2. Squeeze dry in a clean cloth.

3. Saturate in clean engine oil.

4. Squeeze in a clean, absorbent cloth to remove all

excess oil.

CLEAN ENGINE: Remove dirt and debris with a cloth
or a brush. Do not clean with a forceful spray of
water. Water might contaminate the fuel system.

Periodically clean the muffler area to remove
combustible debris.

-----------------------------------------------------------

Clean Rotating Screen: If your POWER-ARC 4000 is
equipped with an engine that has a rotating screen,
you should clean it as often as needed, to remove dirt
or debris that may collect on the screen. A dirty
screen can result in engine overheating and damage.
(See Figure D.3).

FIGURE D.3 - CLEAN ROTATING

SCREEN/FINGER GUARD/DEBRIS GUARD

1. ROTATING SCREEN

CLEAN COOLING SYSTEM: See Figure D.4. Clean
the internal cooling fins and surfaces to prevent over-
speeding, overheating, and engine damage. Clean
every 100 operating hours or as often as necessary.

FIGURE D.4 - CLEAN COOLING SYSTEM

1. REMOVE DIRT FROM THESE AREAS.

POWER-ARC 4000

CAUTION

CAUTION

1

1

WARNING