OPERATION

B-2

LIMITATIONS

• The POWER-ARC 4000 is not recommended for

any processes besides those that are normally per-
formed using stick welding (SMAW) procedures.

• The POWER-ARC 4000 is not recommended for

pipe thawing.

• During welding, generator power is limited to 100

watts, and output voltages can drop from 120 to 80
volts and 240 to 160 volts. Therefore, DO NOT
OPERATE ANY SENSITIVE ELECTRICAL EQUIP-
MENT WHILE YOU ARE WELDING.

CONTROLS AND SETTINGS

All generator/welder controls are located on the
Output Control Panel. Gasoline engine controls are
mounted on the engine. See Figures B.1 and B.2 and
the explanations that follow.

GENERATOR/WELDER CONTROLS

See Figure B.1 for the location of the following fea-
tures:

1.

CURRENT CONTROL DIAL: Adjusts continuous
current output. The amperages on the dial corre-
spond to the average amperages needed for spe-
cific Lincoln welder rods.

2.

ELECTRODE SELECTION GUIDE: Provides rec-
ommended electrode type, size, and welder out-
put setting based on the thickness of the work.

3.

WELD OUTPUT TERMINAL (TO ELECTRODE
HOLDER) WITH 1/2 - 13 FLANGE NUT: Provides
the connection point for either the electrode hold-
er or the work cable. (Because the POWER-ARC
4000 is an AC output machine, either output ter-
minal can be used for either cable.)

POWER-ARC 4000

POWER ARC 4000

POWER ARC 4000

ELECTRODE SELECTION GUIDE

ELECTRODE SELECTION GUIDE

80

80

90

90

100

100

70

70

AMPS

AMPS

AMPS

AMPS

AMPS

AMPS

AMPS

AMPS

WARNING

AMPS

AMPS

125

125

GENERATOR

GENERATOR

8

7

6

5

3

1

2

4

9

FIGURE B.1 – OUTPUT PANEL CONTROLS

1. CURRENT CONTROL DIAL
2. ELECTRODE SELECTION GUIDE
3. WELD OUTPUT TERMINAL (TO ELECTRODE HOLDER) WITH 1/2 - 13 FLANGE NUT
4. WELD OUTPUT TERMINAL (TO WORK) WITH 1/2 - 13 FLANGE NUT
5. GROUND STUD
6. 20 AMP CIRCUIT BREAKERS (2)
7. 20 AMP, 240 VOLT RECEPTACLE
8. 20 AMP, 120 VOLT DUPLEX RECEPTACLE
9. TACHOMETER / HOURMETER (CODE 10930 ONLY)