beautypg.com

Troubleshooting, Caution – Lincoln Electric IM867 PIPELINER LN-23P User Manual

Page 18

background image

E-3

TROUBLESHOOTING

E-3

PIPELINER

®

LN-23P

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Improper wire speed control.

Can’t obtain required voltage.

1. Faulty printed circuit board,

faulty rheostat, or faulty motor.

1. Defective power source CV

Adapter or Wire Feed Module.

2. On SAM welders, constant

voltage control must be adjusted
to give required voltage and
mode switch must be set to
constant voltage position.

3. On DC-600 and R3S welders,

fine voltage control switch must
be set to remote position.

4. Broken lead(s) in 75-76-77

(A-B-C) control circuit.

5. Defective voltage control

rheostat.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.