beautypg.com

Installation, Caution – Lincoln Electric IM867 PIPELINER LN-23P User Manual

Page 10

background image

A-3

INSTALLATION

PIPELINER

®

LN-23P

A-3

WIRE DRIVE ROLLS AND GUIDE TUBES

The LN-23P is shipped with the proper drive rolls and
guide tubes factory installed. Do not adjust the idle roll
tension adjusting screw. If the idle roll tension must be
relieved temporarily, see “A” and “B” of Maintenance
Section.

OPTIONAL FEATURES INSTALLATION

INNERSHIELD GUN AND CABLE

Unclip the rubber retaining strap that holds the wire
enclosure cover in place and remove the cover.

Push the wire drive section door latch towards the
rear of LN-23P and open door.

Loosen the gun locking set screw in the conductor
block on the front of the gear box with a 3/16 hex
Allen wrench.

Lay the cable out straight. Insert the connector on
the conductor cable through the large grommet in
the front of the wire drive section and into the brass
block on the front of the gear box. Make sure it is
all the way in and tighten the locking set screw with
a 3/16 hex Allen wrench. Keep this connection
clean and bright.

Connect the 3-pin gun trigger connector to the
lower receptacle.

If the gun cable being used has a reduced speed
switch, connect the 4-pin reduced speed switch
connector to the upper receptacle. If the reduced
speed switch is not used, install the protective cap
on the upper receptacle.

K-276 ENCLOSED 50lb.WIRE REEL SUPPORT
Installation and loading instructions (M-13153) are
supplied with the kit.

------------------------------------------------------------------------

CAUTION