Installation, Mobiflex 100-nf portable extraction fan, General mobiflex 100-nf portable extraction fan – Lincoln Electric IM629 Mobiflex 100-NF Portable Fan User Manual
Page 8: Airflow, General

MOBIFLEX 100-NF PORTABLE FAN
A-1
INSTALLATION
A-1
Technical Specifications- Mobiflex 100-NF Portable Fan,
Hose and Hood Set, and Exhaust/Extension Set
NOTE:
Technical Specifications are subject to change without
prior notice. Specifications and guarantees are valid only when
specified spare parts and filters are used.
Mobiflex 100-NF Portable Extraction Fan
Sales Spec.
K1666-1
Input Voltage
115V, 1 Ph, 60 Hz
Rated Current Draw
10.0 A
Power Rating
0.75 kW
Sound Level
69 dB(A)
Weight
37.5 lbs. (17 kg)
GENERAL
Mobiflex 100-NF Portable Extraction Fan
Extraction Type:
Low Vacuum, High Volume
Airflow Rate
With K1668-1 only
765 CFM (1,300 m
3
/h)
With K1668-1 and K1668-2 676 CFM (1,150 m
3
/h)
AIRFLOW
Min. Temperature
41
o
F (5
o
C)
Max. Temperature
113
o
F (45
o
C)
Max. Rel. Humidity
80%
AMBIENT CONDITIONS
PRESSURE DROP - Mobiflex 100-NF
Fan
(fan only, with no hose attached)
Vacuum (inches WG) vs. Air Flow (CFM)
Sales Spec.
K1668-1 Hose and Hood Set
K1668-2 Exhaust/Extension Set
Hose Length
16.4 ft. (5 m)
Nominal Diameter
6.3 in. (160 mm)
Weight
K1668-1 22 lbs. (10 kg)
K1668-2 18 lbs. (8 kg)
GENERAL
10"
(250 mm)
9.3"
(230 mm)
ш
6.3"
(
ш
160 mm)
23" (587 mm)
11" (275 mm)
9"
(225 mm)
12"
(300 mm)
7"
(180 mm)
ш
6.3
(
ш
160 mm)
ш
6.3"
(
ш
160 mm)
A
50/60 Hz
B
0"/H O
(0 Pa)
1.61"/H O
(400 Pa)
3.21"/H O
(800 Pa)
4.82"/H O
(1200 Pa)
6.43"/H O
(1600 Pa)
8.03"/H O
(2000 Pa)
9.64"/H O
(2400 Pa)
0
CFM
(0 m /h)
246
CFM
(400m /h)
492
CFM
(800m /h)
738
CFM
(1200m /h)
984
CFM
(1600m /h) 1,230
CFM
(2000m /h)
2
2
2
2
2
2
2
3
3
3
3
3
3