beautypg.com

Operating instructions, Warning – Lincoln Electric IM463 IDEALARC DC-650 Pro User Manual

Page 15

background image

15

OPERATING INSTRUCTIONS

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or

electrode with skin or wet clothing.

Insulate yourself from work and

ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------

FUMES AND GASES can be

dangerous.

Keep your head out of fumes.

Use ventilation or exhaust to remove

fumes from breathing zone.

------------------------------------------------------------------------

WELDING SPARKS can cause fire or

explosion.

Keep flammable material away.

Do not weld on closed containers.

------------------------------------------------------------------------

ARC RAYS can burn eyes and skin.

Wear eye, ear and body

protection.

------------------------------------------------------------

See additional warning information at

front of this operator

s manual.

-----------------------------------------------------------

WARNING

GMAW (MIG) Operation

Properly connect a wire feeder control cable to either
the terminal strip or to the Wire Feeder Receptacle.

If welding electrode positive, connect the electrode
cable to the

+

output studs. Connect the work cable

to the center output studs, labeled

GMAW, FCAW

.

Do not make any connections to the left hand pair of
output studs.

Set the control panel switches as follows:

------------------------------------------------------------------------

Mode:

GMAW

------------------------------------------------------------------------

Output

Local or Remote (See

Output Control

Control:

Switch

)

------------------------------------------------------------------------

LN-9/NA-5:

Off, unless an LN-9 or NA-5 is being
used.

------------------------------------------------------------------------

Wire Feeder Set to match the electrode polarity.
Voltmeter:

------------------------------------------------------------------------

Output
Terminals:

Remote

------------------------------------------------------------------------

If using Local output control, preset the desired
welding voltage using the Output potentiometer and
the voltmeter. If using Remote Output control, preset
the welding voltage using a remote control, or with the
voltage control on the wire feeder. If using an LN-9,
see

Operation with LN-9 or NA-5 Wire feeder

section.

Set up the wire feeder according to the wire feeder
instruction manual.

When the gun trigger is pulled (or the weld sequence
is started) and an arc is struck, the voltmeter will
display the welding voltage preset at the output studs
of the DC-650 PRO, and the ammeter will display the
output current.