Installation, Technical specifications - idealarc, Ac-1500 – Lincoln Electric IM914 IDEALARC AC-1500 User Manual
Page 8

A-1
INSTALLATION
IDEALARC
®
AC-1500
A-1
*
Thomas & Betts wire terminals (or equal) recommended above are required to comply with applicable U.L. standards for safety. A #30 hex
(Allen) key wrench is required for assembly of terminals to wire. Based on National Electrical Code - 100% Duty Cycle 40˚C (104˚F)
Ambient.
Weight
1649lbs.
748(kg.)
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT (SMAW)
PHYSICAL DIMENSIONS
RECOMMENDED INPUT WIRE GROUNDING CONDUCTOR AND FUSE SIZES*
Standard Voltage
Duty Cycle
100%
Current Range
240/1500
Volts
Amps
Maximum Open
Circuit Voltage
“MIN” Terminal
30-44
240-600
“MED” Terminal
38-44
460-1060
“MAX” Terminal
44
890-1500
Depth
38.00in.
(965.2mm.)
Width
22.30 in.
(566.4mm.)
Height
53.50 in.
( 1358.9mm.)
AMPS AC
1500 @ 44 Volts
Input Current at 100% Rated Output
Single Phase Output
Scott Connection
380/50/60
Rated Input Current With P.F. Capacitors
310 Amp Single Phase
358 Amp Scott-connection
310
358
TECHNICAL SPECIFICATIONS - IDEALARC
®
AC-1500
86
RATING: IP21 ENCLOSURE, INSULATION 155°(F)
Idle Current With P.F. Capacitors
70
Power Factor @ Rated load With P.F. Capacitors
71%
Power Input Wires
Grounding Conductor
Input Amps
Copper Wire Size – 75˚C in Conduit
Super Lag Fuses
Size in Amps
Input
Volts/
Hz.
380/50
310
358 500MCM 31013 600MCM 31015 #3 31007 #2 31007 400
500
(250mm
2
)
(300mm
2
)
(25mm
2
)
(35mm
2
)
1
Scott 1 T&B Scott T&B 1 T&B Scott T&B 1 Scott
Phase
Conn. Phase Term. Conn. Term. Phase Term. Conn. Term. Phase Conn.