GX 271 Chopper LPG

C-3

C-3

ACCESSORIES - CONNECTION DIAGRAMS

6 PIN

AMPHENOL

TO WORK

14 PIN

AMPHENOL

LN-25

N.E. PLACE THE WELDING TERMINALS SWITCH IN THE "ALWAYS ON" POSITION.

N.C. PLACE THE MODE SWITCH IN THE "WIRE WELDING-CV" POSITION.

N.F. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

S24095-1

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

ELECTRODE CABLE

WIRE FEEDER

TO WORK

WORK CLIP LEAD

OPTIONAL K857

REMOTE CONTROL

GX-271 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

WARNING

or service this equipment.

Keep away from moving parts.

WITH OPTIONAL K857 REMOTE CONTROL

Only qualified personnel should install,use

N.B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER
VOLTMETER SWITCH TO MATCH THE POLARITY OF THE ELECTRODE CABLE.

N.D. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

Do not operate with panels open.

before servicing.

Disconnect NEGATIVE (-) BATTERY LEAD

Do not touch electrically live parts.

Keep guards in place.

ELECTRODE

TO WORK

A

GX-271 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

S24095-2

A

N.D. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. CONNECT WELDING CABLES TO OUTPUT STUDS FOR DESIRED POLARITY. POSITION THE WIRE FEEDER
VOLTMETER SWITCH TO MATCH THE POLARITY OF THE ELECTRODE CABLE.

ELECTRODE CABLE

WIRE FEEDER

OPTIONAL K444-1
REMOTE CONTROL

TO WORK

WORK CLIP LEAD

Keep guards in place.

or service this equipment.

Keep away from moving parts.

Only qualified personnel should install,use

WARNING

WITH OPTIONAL K444-1 REMOTE CONTROL

6 PIN

AMPHENOL

14 PIN

AMPHENOL

TO WORK

LN-25

Do not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

ELECTRODE

TO WORK

N.E. PLACE THE WELDING TERMINALS SWITCH IN THE "ALWAYS ON" POSITION.

N.F. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.