beautypg.com

Troubleshooting, Caution – Lincoln Electric IM839 DEVICENET MODULE User Manual

Page 15

background image

B-2

TROUBLESHOOTING

B-2

DEVICENET MODULE

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Device does not go on line.

1. 24v bus power

2. Baud rate

3. MAC address

4. Termination

5. Wiring

6. EDS files

1. Verify that LED 2 on the Power

Wave

s DeviceNet Module is on

when the DeviceNet network is
powered. This should be done
with the power on the Power
Wave turned off.

2. Verify the Baud rate setting on the

Power Wave and on the
DeviceNet Master are the same.
The Configuration section of
Observer displays the Power
Wave

s baud rate.

3. Verify the Device Net MAC

address is correct. The
Configuration section of Observer
displays the Power Wave

s MAC

address.

4. Verify that the Device Net bus is

terminated correctly.

5. Verify the wiring of all multi-port

taps and field attachable ends.

6. Verify that the correct EDS files

are being used if they are needed.
The Configuration section of the
Observer application displays the
current Product Code and Vendor
Revision of the Power Wave.