ENGINE CONTROLS (Items 1 through 8)

1. RUN STOP SWITCH
When placed in the

RUN

position, this switch ener-

gizes the fuel solenoid and other electric accessories.
When placed in the

STOP

position, the flow of fuel to

the injection pump is stopped to shut down the engine.
(Note: If the switch is left in the "RUN" position and the
engine is not running, the fuel solenoid will be engaged
for 15 seconds and then shut down. This is to protect
the battery from discharge. After 15 seconds, the Run
/ Stop switch must be toggled off then on before start-
ing.)

2. START PUSHBUTTON
Energizes the starter motor to crank the engine. With the
engine "Run / Stop" switch in the "Run" position, push and
hold the Start button to crank the engine; release as the
engine starts. Start button must be depressed for a minimum
of two seconds. Do not press while engine is running since
this can cause damage to the ring gear and/or starter motor.