Installation, Connection of lincoln electric wire feeders, Warning caution – Lincoln Electric IM763 Commander 500 User Manual
Page 16

A-8
INSTALLATION
COMMANDER 500
A-8
CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS
Shut off welder before making any electrical connec-
tions.
------------------------------------------------------------------------
CONNECTION OF THE LN-25 TO THE
COMMANDER 500
The LN-25 with or without an external contactor may
be used with the Commander 500. See the appropri-
ate connection diagram in the DIAGRAMS section.
NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the Commander 500.
•
Shut the welder off.
•
For electrode Positive, connect the electrode cable
from the LN-25 to the
“
+
”
terminal of the welder and
work cable to the
“
-
”
terminal of the welder. For elec-
trode Negative, connect the electrode cable from the
LN-25 to the
“
-
”
terminal of the welder and work
cable to the
“
+
”
terminal of the welder.
•
Attach the single lead from the front of the LN-25 to
work using the spring clip at the end of the lead. This
is a sense lead to supply current to the wire feeder
motor; it does not carry welding current.
•
Set the SELECTOR switch to the
“
CV-WIRE
”
posi-
tion.
•
Set the
“
WELDING TERMINALS
”
switch to
“
WELD
TERMINALS ON
”
•
Adjust the
“
ARC CONTROL
”
knob to desired crisp-
ness. Generally, welding is best if the
“
ARC CON-
TROL
”
is set to SOFT for MIG and CRISP for
Innershield. You may however, want to start in the
middle and adjust (as needed) from there.
•
If you are using an LN-25 with an internal contactor,
the electrode is not energized until the gun trigger is
closed.
If you are using an LN-25 without an internal contactor,
the electrode will be energized when the Commander
500 is started.
------------------------------------------------------------------------
•
When the gun trigger is closed, the current sensing
circuit will cause the wire to feed and the welding
process will start.
CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 500
•
Shut the welder off.
•
Connect the LN-7 or LN-8 per instructions on the
appropriate connection diagram in the DIAGRAMS
section.
•
Set the
“
WIRE FEEDER VOLTMETER
”
switch to
either
“
+
”
or
“
-
”
as required by the electrode being
used.
•
Set the
“
SELECTOR
”
switch to the
“
CV-WIRE
”
posi-
tion.
•
Adjust the
“
ARC CONTROL
”
knob to desired
Crispness. SOFT for MIG and CRISP for Innershield.
•
Set the
“
WELDING TERMINALS
”
switch to the
“
REMOTELY CONTROLLED
”
position.
WARNING
CAUTION