Troubleshooting, Caution – Lincoln Electric IM676 RED-D-ARC PM 255 User Manual
Page 27
E-2
E-2
TROUBLESHOOTING
PROBLEMS
(SYMPTOMS)
Major Physical or Electrical
Damage is Evident
There is no wire feed or open cir-
cuit voltage when the gun trigger is
pulled. The machine displays are
lit indicating input power to the PM
255.
Output voltage and wire feed is pre-
sent when gun trigger is not pulled
(not activated).
Machine output is low. Welds are
“
cold”, weld bead is rounded or
bumped up demonstrating poor
wetting into plate.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. Contact your Local Lincoln
Authorized Field Service Facility.
1 The gun trigger or cable may be
faulty. Check or replace gun
assembly.
2. The thermal protection circuit
may be activated. If this is the
case, the display will show “too
hot”. Allowing the machine to
cool will clear the error condition.
3. Make sure input voltage is cor-
rect and matches nameplate rat-
ing and reconnect panel configu-
ration.
1. Remove gun assembly from
machine. If problem is solved
gun assembly is faulty. Repair or
replace.
2. If problem persists when gun
assembly is removed from
machine then the problem is
within the PM 255.
1. Check input voltage. Make sure
input voltage matches name-
plate rating and reconnect panel
configuration.
2. Make sure settings for wire feed
speed and voltage are correct
for process being used.
3. Make sure output polarity is cor-
rect for process being used.
4. Check welding cables and gun
assembly for loose or faulty con-
nections.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Authorized
Field Service Facility.
OUTPUT PROBLEMS
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
LOCAL AUTHORIZED FIELD SERVICE FACILITY
for assistance before you proceed.
CAUTION
PM 255
Observe all Safety Guidelines detailed throughout this manual