Preheating device with automatic heating
timer
(additional equipment)

The preheating light „5“ lights up additionally at
temperatures below 0° Celsius (Fig. 13).

– After the light has gone out, start the engine

without delay.

Automatic shut-down function
(additional equipment)

This is characterized by a brief flashing of all
pilot lamps once the starter key has been turned
to position I (Fig. 13).

Important !
If the engine cuts out immediately after starting
or switches off by itself during operation, a mon-
itoring element in the automatic shutdown sys-
tem has tripped. The corresponding indicator
light (Fig. 13, positions 2 - 4) will come on. After
the engine has stopped, the display continues to
glow for about 2 minutes.
The electrical device then switches itself off au-
tomatically.
The display lights up again after the start key
has been turned back to position 0 and then to
position I again.
Trace and eliminate the cause of the
operating fault before trying to restart the
engine (see chapter 6)
.

The display light goes out when the engine is
next started.

Even with automatic shutdown monitoring the
oil level must be checked every 8 – 15 operat-
ing hours
(chapter 5.2.1.).