HATZ Diesel 1D90 User Manual
Page 18

Automatic electrical shutdown system
(additional equipment)
This is characterized by a brief flashing of all
pilot lamps once the starter key has been turned
to position I (Fig. 24).
Important !
If the engine cuts out immediately after starting
or switches off by itself during operation, a
monitoring element in the automatic shutdown
system has tripped. The corresponding indicator
light (Fig. 24, positions 2 - 4) will come on.
After the engine has stopped, the display con-
tinues to glow for about 2 minutes.
The electrical device then switches itself off au-
tomatically.
The display lights up again after the start key
has been turned back to position 0 and then to
position I again.
Trace and eliminate the cause of the operating
fault before trying to restart the engine
(see chapter 6).
The display light goes out when the engine is
next started.
Even with automatic shutdown monitoring the
oil level must be checked every 8 – 15 operat-
ing hours (Chapter 5.2.1.).
4.3.
Stopping the engine
Never stop the engine by moving the
decompression lever. During breaks
in work or at the conclusion of the working pe-
riod, keep the starting handle and starting key
in a safe place, out of reach of unauthorized
persons.
25
Never stop the engine by actuating the
decompression lever !
Risk of damage to the engine.
26
– Move speed control lever „1“ back to the
STOP position.
2396 / 3
2
1
START
START
STOP
STOP
0000 050 616 01