4.2.4. Electric starter

For preparations to start, see Chapter 4.2.1.

– The decompression lever remains in pos. „0“.

Starting procedure

24

– Insert the key to its stop and turn it to

position I.

– Battery charge telltale „2“ and oil pressure

warning „3“ must light up.

– Turn start key to position II (fig. 24).

– As soon as the engine runs, release the start

key. It must return to position I by itself and
remain in this position during operation.
The battery charge telltale and oil pressure
warning must go out immediately after start-
ing. Indicator light „1“ is on when the engine
is in operation.

– If anything seems to be incorrect, stop the en-

gine immediately and trace and rectify the fault
(chapt. 6).

– The engine temperature display „4“ (additional

equipment) lights up if the temperature at the
cylinder head becomes too high.
Switch off the engine and trace and elimi-
nate the cause of the problem,
chap. 6.

– Always turn the start key back to position 0

before re-starting the engine. The repeat lock
in the ignition lock prevents the starter motor
from engaging and possibly being damaged
while the engine is still running.

Never operate the electric starter when
the engine is running or coasting to a

standstill. There is a risk of broken starter pin-
ion or ring gear teeth.

Important:
If a start protection module is installed, the start
key has to be returned to position 0 for at least
8 seconds if the engine has failed to start before
a further attempt to start the engine can be
made.

Preheating device with automatic
heating timer

(additional equipment)

The preheating light „5“ lights up additionally at
temperatures below 0° Celsius (Fig. 24).

– After the light has gone out, start the engine

without delay.

1
2
3
4

5

16