Resistance values of components – Armstrong World Industries 6100 User Manual
Page 42

42
Resistance Value of 6100/6300 Components
Component
Voltage
Resistance
Fill Valve
24Vac
18W
Drain Valve
24Vac
10W
Contractor
24Vac
7-9W
Thermocouple in Heating Elements -
0.51W
Heating Elements
208Vac and 380Vac 3kW
220Vac
46.0-48.6W
240Vac and 380Vac 3kW
240Vac
55-58W
480Vac and 380Vac 3kW
277Vac
72-78.2W
600Vac and 380Vac 3kW
346 Vac
112.4-122.4W
208Vac and 380Vac15/30kW
220Vac
9.2-10.7W
240Vac 15/30kW
240Vac
10.9-12.6W
480Vac 15/30kW
277Vac
14.5-16.8W
600Vac 15/30kW
346Vac
22.7-26.3W
208Vac and 380Vac9/18kW
220Vac
15.3-17.7W
240Vac 9/18kW
240Vac
18.2-21.1W
480Vac 9/18kW
277Vac
24.3-28.2W
600Vac 9/18kW
346Vac
37.9-43.9W
Power Transformer
120Vac
13.6W across H1-H2
15.1W across H3-H4
208Vac
22W across H1-H2
240Vac
29W across H1-H2
380Vac
77W across H1-H2
480Vac
125W across H1-H2
600Vac
194W across H1-H2
Power Transformer
(secondary)
All
Voltage
0.6W across X1-X2
0.4W across X1-X2
Resistance Value of 6500/6700 Components
Component
Voltage
Resistance
Fill Valve
24Vac
8.8W
Drain Valve
24Vac
4.1W
Thermocouple in Heating Elements
-
0.51W
Heating Elements
208, 240, 380V, 30/33, 5/40/45/50, 3/60kW 240Vac
7.4-9.1W
380V 48/72/96kW
220Vac
5.2-6.3W
480V 48/72/96kW
277Vac
8.1-10.0W
600V 48/72/96kW
346 Vac
12.8-15.7W
Power Transformer
Primary Loop
208Vac
18W across H1-H2
240Vac
21W across H1-H3
277Vac
24W across H1-H4
380Vac
40W across H1-H5
480Vac
22W across H1-H6
600Vac
22W across H1-H2
Secondary Loop
208Vac
1W across X1-X2
240Vac
1W across X1-X2
277Vac
1W across X1-X2
380Vac
1W across X1-X2
480Vac
1W across X1-X2
600Vac
1W across X1-X2
Note: All measurements should be made with the main power off
and the wires to the component being tested disconnected.
Resistance Values of Components