beautypg.com

Enable ip icmpreply, Show ip icmpreply – Allied Telesis 86222-27 User Manual

Page 41

background image

Patch 86222-27 For Rapier Switches

41

Patch 86222-27 for Software Release 2.2.2
C613-10319-00 REV Z

If ALL is specified, all configurable ICMP message replies are disabled. If
NETUNREACH is specified, all network unreachable message replies are
disabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host
unreachable message replies are disabled (RFC792 Type 3 Code 1). If
REDIRECT is specified, all ICMP redirect message replies are disabled (RFC792
Type 5 Code 0, 1, 2, 3).

Example

To disable all configurable ICMP messages, use the command:

DISABLE IP ICMPREPLY=ALL

See Also

ENABLE IP ICMPREPLY
DISABLE IP ECHOREPLY
SHOW IP ICMPREPLY

ENABLE IP ICMPREPLY

Syntax

ENABLE IP

ICMPREPLY[={ALL|NETUNREACH|HOSTUNREACH|REDIRECT}]

Description

This command enables ICMP reply messages.

If ALL is specified, all configurable ICMP message replies are enabled. If
NETUNREACH is specified, all network unreachable message replies are
enabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host
unreachable message replies are enabled (RFC792 Type 3 Code 1). If
REDIRECT is specified, all ICMP redirect message replies are enabled (RFC792
Type 5 Code 0, 1, 2, 3).

Example

To enable all configurable ICMP messages, use the command:

ENABLE IP ICMPREPLY=ALL

See Also

ENABLE IP ECHOREPLY
DISABLE IP ICMPREPLY
SHOW IP ICMPREPLY

SHOW IP ICMPREPLY

Syntax

SHOW IP ICMPREPLY

Description

This command display the status of configurable ICMP messages (Figure

Figure 1: Example output from the SHOW IP ICMPREPLY command:

SHOW IP ICMP REPLY MESSAGES

--------------------------------------------------------------------------------

ICMP REPLY MESSAGES:

Network Unreachable ................ disabled

Host Unreachable ................... disabled

Redirect ........................... enabled

--------------------------------------------------------------------------------