14

POWER CONNECTIONS AND WIRING MUST BE CARRIED OUT BY

AN AUTHORISED ELECTRICIAN.

DANGER - Hazardous suction. Do not block water entry into filtration

system with any part of your body as the pressure can trap hair or body

parts, causing severe injury or death. Do not block suction.

Turn off pump immediately if someone becomes trapped.

Caution! Do not add chemicals directly to the pool skimmer. Adding

undiluted chemicals may damage pump and filter and void warranty.

Small children using the pool or spa must ALWAYS have close adult

supervision.

Routine Maintenance tasks - to maximise the life of your pool equipment

& personal safety, use this checklist once a week. Turn pump off first.

a.

Make sure that any pressure gauges are in working condition and the

operating pressure is within limits as specified on the product.

b.

Make sure that each suction inlet, and main drain has a cover that is

securely attached and in safe working condition.

c.

Make sure that all skimmer cover are securely attached and in safe

working condition. These should be replaced every 3 to 4 years.

d.

Remove any obstructions or debris from the main drain cover.

e.

Ensure the skimmer baskets and the pump hair and lint pots are free

of leaves and debris at least once a week.

f.

Remove obstructions and combustibles from around the pump motor.

g.

Make sure all wiring connections are clean and that all wiring and

electrical equipment is in good condition. Damaged wiring must be

repaired or replaced by a qualified electrician as soon as damage is

discovered.

h.

Check water balance and sanitiser levels at your local pool shop.

WARNING! Pump suction is hazardous and can trap and drown or disembow-

el bathers. Do not block suction. Do not use or operate swimming pools, spas

or spa baths if a suction cover is broken, missing or loose. Two suction covers

and inlets must be provided into every pump to avoid suction entrapment.