Trouble shooting rainbank, Symptom: pump will not switch off, Symptom: pump will not switch on – Davey RAINBANK WALL MOUNTED CABINET SYSTEM User Manual
Page 16
![background image](/manuals/361858/16/background.png)
16
tRouBLe SHootInG RAInBAnk
®
Symptom: Pump will not switch off
1. Pump plugged directly into power outlet.
Plug lead from pump into base of RainBank
®
as per installation instructions on pg 10.
2. water is still being used.
Check all taps, toilets and appliances connected to RainBank
®
system to ensure
they are turned off.
3. water is leaking on discharge side of RainBank
®
system.
Check for leaks and repair.
Symptom: Pump will not switch on
1. Pump not plugged in.
Plug pump into base of RainBank
®
and RainBank
®
into power supply.
2. no power supply to pump.
Contact electrician and have power restored.
3. no water in tank.
Check water level in tank.
4. Mains water supply not connected to RainBank.
RainBank
®
system must have a pressurised water supply connected to inlet.
Press ‘manual override’ button to simulate mains water flowing.
5. Mains supply to RainBank
®
turned off.
Turn on mains water supply. Press ‘manual override’ button to simulate mains
water flowing. Pump will start if rain water is available.
6. Pump is faulty.
To confirm if the fault is within the pump, plug the pump directly into power point
and check to see if it starts. If the pump starts plug the pump back into the
RainBank
®
and continue fault finding. If the pump does not start contact your
supplier for further advice.
7. Mains water flow is too low.
Ensure flow at most distant outlet is above 5 litres per minute.