ML50 Instruction Manual Power Supplies
ML50 Bedienungsanleitung für Stromversorgung

Technical Data

1)

Technische

Daten

1)

ML50.100

ML50.109

14)

ML50.101

ML50.111

15)

ML50.102

ML50.105

Output Voltage

Ausgangsspannung

nom.

DC 24-28V

DC 24-28V

DC 12-15V

17

)

DC 48-56V

Factory Setting at Full Load

Werkseinstellung bei Nennlast

typ.

24.5V 24.0V

16

) 15.0V

17

)

48.0V

Output Current

Ausgangsstrom

nom.

2.1A at 24V
1.8A at 28V

2.1A at 24V
1.8A at 28V

4.2A at 12V
3.3A at 15V

1.05A at 48V

0.9A at 56V

Output Power

Ausgangsleistung

nom.

50W

50W 50W

50W

Output Ripple & Noise Voltage

2)

Ausgangswelligkeit

2

)

max.

50mVpp

50mVpp 50mVpp

50mVpp

AC Input Voltage

AC Eingangsspannung

nom.

AC 100-240V

-15%/+10%

AC 100-240V

-15%/+10%

AC 100-240V

-15%/+10%

AC 100-240V

-15%/+10%

Input Frequency

Eingangsfrequenz

nom.

50-60Hz

50-60Hz 50-60Hz

50-60Hz

AC Input Current

3)

AC

Eingangsstrom

3)

typ.

0.83A / 0.52A

0.83A / 0.52A

0.83A / 0.52A

0.83A / 0.52A

Power Factor

3)

Leistungsfaktor

3)

typ.

0.56 / 0.48

0.56 / 0.48

0.56 / 0.48

0.56 / 0.48

Allowed Voltage L or N to Earth

Erlaubte Spannung L oder N zu Erde

max.

264Vac / 375Vdc

264Vac / 375Vdc

264Vac / 375Vdc

264Vac / 375Vdc

DC Input Voltage

13)

DC

Eingangsspannung

13)

nom.

DC 110-300V

-20%/+25%

DC 110-300V

-20%/+25%

DC 110-300V

-20%/+25%

DC 110-300V

-20%/+25%

Input Inrush Current

4)

Einschaltspitzenstrom

4)

typ.

17A / 35A

17A / 35A

17A / 35A

17A / 35A

Hold-up Time

3)

Pufferzeit

3)

typ.

40ms / 180ms

40ms / 180ms

40ms / 180ms

40ms / 180ms

Efficiency

3)

Wirkungsgrad

3)

typ.

88.4% / 89.0%

88.4% / 89.0%

89.4% / 90.5%

89.7% / 90.5%

Power Losses

3)

Verlustleistung

3)

typ.

6.6W / 6.2W

6.6W / 6.2W

6.1W / 5.3W

6.2W / 5.3W

Operational Temperature Range Betriebstemperaturbereich

nom.

-10°C - +70°C

-10°C - +70°C

-10°C - +70°C

-10°C - +70°C

Output Derating

Leistungsrücknahme

+60°C to +70°C

1.3W/°C

1.3W/°C

1.3W/°C

1.3W/°C

Storage Temperature Range

Lagertemperaturbereich

nom.

-40°C - +85°C

-40°C - +85°C

-40°C - +85°C

-40°C - +85°C

Humidity

5)

Feuchte

5)

IEC 60068-2-30

5 - 95% r.H.

5 – 95% r.H.

5 - 95% r.H.

5 - 95% r.H.

Vibration Schwingen

IEC 60068-2-6

2g

2g

2g

2g

Shock Schocken

IEC 60068-2-27

15g 6ms, 10g 11ms

15g 6ms, 10g 11ms

15g 6ms, 10g 11ms

15g 6ms, 10g 11ms

Degree of Pollution (non-conductive) Verschmutzungsgrad

(nicht leitend)

EN 50178, IEC 62103

2

2

2

2

Degree of Protection

Schutzart

EN 60529

IP20

IP20

IP20

IP20

Class of Protection

Schutzklasse

IEC 61140

I

6)

I

6)

I

6)

I

6)

Over-temperature Protection

Übertemperaturschutz

OTP

No / Nein

No / Nein

No / Nein

No / Nein

Output Over-voltage Protection Überspannungsschutz

am

Ausgang

OVP, max.

40Vdc

40Vdc

20Vdc

60Vdc

Leakage Current

7)

TN/TT-mains PE-

Ableitstrom

7)

TN/TT- Netze

max.

0.23mA / 0.40mA

0.23mA / 0.40mA

0.23mA / 0.40mA

0.23mA / 0.40mA

IT-mains

IT- Netze

0.49mA / 0.81mA

0.49mA / 0.81mA

0.49mA / 0.81mA

0.49mA / 0.81mA

Return Voltage Resistance

8)

Rückspeisefestigkeit

8)

max.

35Vdc

35Vdc 22Vdc

63V

Parallel Use

11)

Parallelschaltbar

11)

-

Yes / Ja

Yes / Ja

Yes / Ja

Yes / Ja

Serial Use

12)

Serienschaltbar

12)

-

Yes / Ja

Yes / Ja

No / Nein

Yes / Ja

Dimensions

9)

(WxHxD) Abmessungen

9)

(BxHxT)

nom.

45x75x91mm

45x75x91mm 45x75x91mm

45x75x91mm

Weight Gewicht

max.

240g / 0.53lb

240g / 0.53lb

240g / 0.53lb

240g / 0.53lb

DC-OK Signal

DC-OK Signal

Yes / Ja

Yes / Ja

No / Nein

No / Nein

1) All parameters are specified at 230Vac input voltage, TN- TT- IT-mains, nominal output

current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.

2) 50-Ohm measurement, bandwidth 20MHz
3) at 120Vac, 60Hz / 230Vac 50Hz
4) Peak value at 120Vac / 230Vac, at an ambient temperature of 40°C and cold start.
5) Do not energize while condensation is present.
6) PE connection required (Ground).
7) Leakage current at 132Vac, 60Hz / 264Vac, 50Hz
8) Loads such as decelerating motors and inductors can feed voltage back to the output of the

power supply. The figure represents the maximum allowed feed back voltage

9) Depth without DIN-rail.
11) ML50.101, ML50.111: These units are optimized for parallel operation and are equipped with

the “Parallel Use” feature. The units can be used in parallel over the entire temperature range.

ML50.100, ML50.102, ML50.105, ML50.109: These units are equipped with the standard
“Single Use” output characteristic. There is no current share between the units, make sure
that the ambient temperature stays below 45°C.

A fuse or diode on the output of each unit is required if more than three units are connected in
parallel.

12) Use only power supplies of the same type. The total output voltage should not be >150Vdc.
13) Use a battery or a similar DC source. Connect +pole to L and –pole to N. A supply from the

intermediate DC-bus of a frequency converter is not recommended and can cause a
malfunction or damage the unit. Additional tests might be necessary during the approval
process of a complete system.

14) Version with conformal coated PC-board
15) Version with pluggable screw terminals, depth of unit: 98mm
16) The ML50.101 and ML50.111 are optimized for parallel operation and are equipped with the

“Parallel Use” feature. This feature regulates the output voltage in such a manner that the
voltage at no load is approx. 5% higher than at nominal load.

17) The output voltage range can be set by a jumper (link between pin 4 and 5 of the output

terminals). The output voltage will be 15V when the connection is installed. The voltage will
jump to 12V when removing this connection and then can be adjusted up to 15V.

1) Alle Werte gelten bei 230Vac, TN- TT- IT-Netze, Nennausgangsstrom, 25°C Umgebung und

nach einer Aufwärmzeit von 5 Minuten, wenn nichts anderes angegeben ist.

2) 50-Ohm Messung, Bandbreite 20MHz
3) bei 120Vac, 60Hz / 230Vac, 50Hz
4) Spitzenstrom bei 120Vac / 230Vac, einer Umgebungstemperatur von 40°C und Kaltstart.
5) Nicht betreiben, solange das Gerät Kondensation aufweist.
6) PE Verbindung erforderlich.
7) Ableitstrom bei 132Vac, 60Hz / 264Vac, 50Hz
8) Bremsende Motoren oder Induktivitäten können Spannung zum Ausgang des Netzteils

rückspeisen. Der Wert gibt die max. zulässige Rückspeisespannung an.

9) Tiefe ohne DIN-Schiene
11) ML50.101, ML50.111: Diese Geräte sind für den Parallelbetrieb optimiert und mit dem

“Parallel Use” Feature ausgestattet. Ein Parallelbetrieb ist für den gesamten
Temperaturbereich erlaubt.

ML50.100, ML50.102, ML50.105, ML50.109: Diese Geräte sind mit die standardmäßige
“Single Use” Ausgangscharakteristik ausgestattet. Keine Stromaufteilung zwischen den
Geräten. Erlaubt bis max. 45°C Umgebungstemperatur.

Eine Sicherung oder Diode je Ausgang ist erforderlich wenn mehr als 3 Geräte parallel
geschaltet werden.

12) Nur gleiche Geräte bis zu einer Gesamtspannung von 150Vdc
13) Geeignet sind Batterien oder ähnliche Quellen. Den +Pol an L und –Pol an N anschließen.

Ein Betrieb am Zwischenkreis von Frequenzumrichtern wird nicht empfohlen und kann zu
Defekten oder Fehlfunktionen führen. Bei Zulassung eines Gesamtsystems können zusätzlich
Prüfungen erforderlich werden.

14) Version mit schutzlackierte Leiterplatte
15) Version mit steckbaren Schraubklemmen, Gesamttiefe 98 mm
16) Die ML50.101 und ML50.111 sind für den Parallelbetrieb optimiert und fest auf den Modus

„Parallel Use“ eingestellt. Dieser Modus regelt die Ausgangsspannung so, dass diese im
Leerlauf um etwa 5% höher ist als bei Nennlast.

17) Die Ausgangsspannungsbereich kann mittels eines Jumpers (Verbindung zwischen Pin 4 und

5 der Ausgangsklemme gewählt werden. Bei installierter Verbindung ist die Spannung 15V.
Bei Entfernung der Brücke geht die Spannung auf 12V und lässt sich dann mit dem
Potentiometer bis 15V einstellen.