PreSonus StudioLive 16.0.2 User Manual
Page 62
58
5.5
Using MIDI Control Mode to Remote-Control StudioLive
Ov
er
view
Con
trols
Hook
up
Resour
ces
Getting S
tar
ted
Digital E
ffec
ts
Mast
er C
on
trol
Troubleshooting
and W
arr
an
ty
Digital E
ff
ec
ts
Mast
er C
on
tr
ol
Creating a New Patch on the Roland FC-300
Now that your StudioLive is set up to communicate with the Roland FC-300, you will
need to create a new patch. Remember, you must follow all of the steps in this tutorial
to control your StudioLive as previously described. At the end of this tutorial, we’ll
discuss how to name and save your new patch so you can use it again in the future.
Instant Scene Recall
1. Press the Mode button until the Patch Mode LED is illuminated.
2. Making sure the red LED is illuminated on the
first row of pedals, depress Pedal 1/6.
3. Press the right Parameter button. The LCD will display “PATCH: On MIDI.”
4. Press the Write button so that the LCD displays “Edit MIDI.”
5. Press the Write button again. You will see “001: ----- -----.“
6. Press the right Parameter button.
7. Press the Value Up button so that the LCD displays “001:PC CH#01 PC#001.”
8. The first field defaults to Program Change (“PC”). This is how the
StudioLive recalls Scenes, so you can leave this field as it is.
9. Use the right Parameter button to move to the
next field: MIDI channel number.
10. Set the MIDI channel to 1.
11. Use the right Parameter button to move to the next field: Program Change
number. The number you enter will determine which Scene will be recalled.
12. Use the Value Up button to set the Program Change number to 002.
13. Press the Exit button twice and continue to FXA Preset Recall.
FXA Preset Recall
1. Next we will set CTL Pedal 1 to recall a preset on FXA. Press the
right Parameter button until the LCD displays “CTL1: On MIDI.”
2. Press the Write button so that the LCD displays “Edit MIDI.”
3. Press the Write button again. You will see “001: ----- -----.“
4. Press the right Parameter button.
5. Press the Value Up button so that the LCD displays “001:PC CH#01 PC#001.”
6. The first field defaults to Program Change (“PC”). This is how the
StudioLive recalls FX presets, so you can leave this field as it is.
7. Use the right Parameter button to move to the
next field: MIDI channel number.
8. Set the MIDI channel to 2.
9. Use the right Parameter button to move to the next
field: Program Change number. The number you enter
will determine which FX Preset will be recalled.
10. Use the Value Up button to set the Program Change number to 10.
11. Press the Exit button twice and continue to FXA Assign/Unassign to Mains.