Stuart Turner CHM160-30 B User Manual
Page 17

- 17 -
Cont ...
Briefly reconnect the mains power supply to the pump – the indicator light
should illuminate if the pump has been correctly wired.
Isolate the mains electrical power supply from the pump.
Re fit the terminal box lid ensuring no cables are trapped.
Re fit the four terminal box lid retaining screws, tighten to 0.8 Nm.
7.14
Environment Protection: Your appliance contains valuable materials which can
be recovered or recycled.
At the end of the products’ useful life, please leave it at an appropriate local civic
waste collection point.
Indication
light
Terminal box lid
Retaining screws x 4
Fig. 13 Wiring removed for clarity