6 MAINTENANCE

6.11 Turn off water supplies to the pump and release pressure by

opening water outlets before attempting maintenance.

6.12

Inlet strainer: The inlet strainers may require periodical cleaning. The frequency

of this operation is dependent upon installation conditions.

The strainer is located in the inlet fitting of the pump casing (Fig. 14) and is

removed as follows:-

a) Isolate pump electrically.

b) Release all system pressure.

c) Isolate hot and cold water supplies via the integral pump isolating valve

located in the flexible hoses (see Section 3 - Pump Connections).

d) Disconnect the hot and cold flexible inlet hoses only at the joint where the

hoses connect to the pump inlet fittings (see Section 3 - Pump Connections).

e)

Clean

strainers.

f)

Reassemble

pipework.

g) After maintenance is completed refer to commissioning section for instructions

on re-starting pump.

6.13 No other routine maintenance is required.
6.14

Water scale: As water is heated scale deposits are released in areas of hard

water, scale can cause the mechanical seal to stick if left without use for long

periods. The pump must be run for at least 5 minutes every four weeks to

“exercise” all working parts. Run on cool water. See Section 7 - Technical

Specification for note on water temperature. This particularly applies to guest

bathrooms used infrequently.