Tank filling / emptying float switch, 5m cable – Stuart Turner Floating Switches User Manual

Page 6

background image

Electrical Connections
Emptying (Fig 3 & 4)
To empty a tank or well:
Connect ‘Brown’ and ‘Black’
This will allow the switch to:-
Open when Down
Close when Up

TANK FILLING /
EMPTYING
FLOAT SWITCH

5M CABLE

L

N

L

N

Fig: 4

Fig: 5

Fig: 6

BLACK

BLUE

BLACK

BROWN

Electrical Connections
Filling (Fig 5 & 6)
To fill a tank or well:
Connect ‘Blue’ and ‘Black’
This will allow the switch to:-
Open when Up
Close when Down

BROWN

BLUE

STOP

START

Rating = 16(4)A 230V
Note: - If used with pumps having a continuous rating of 4 Amps or more

the switch must be connected through a relay or contactor.

- Always ensure the wire that is not used is correctly and fully insulated

Fig: 3

STOP

START